44
Dynaset Oy | Menotie 3, 33470 Ylöjärvi | puh. 03 3488 200 | [email protected] | www.dynaset.com
HYDRAULIC ROTARY VANE COMPRESSORS
MAINTENANCE
6.1. MAINTENANCE INTERVALS
ATTENTION!
All maintenance must be complied as they are scheduled in this manual.
The following table provides maintenance schedule for the DYNASET HKL
compressor.
CHECK POINTS
Daily
Monthly or
every 100 h
Every 3
months or
500h
Every 6
months or
1000h
Every 12
months or
2500 h
Check oil level
x
Clean compressor and oil cooler
x
Check system for leaks
x
Change air intake filter
o
x
Clean oil return filters *
x
Change oil, oil filter and oil return filters
x
Change air-oil separating element
x
o = Check / change if necessary
x = Change
NOTE
!
All installation and service of both hydraulics and electric equipment must
be performing experienced personnel only.
6.2. HYDRAULIC FLUIDS
Wide range of standard hydraulic fluids can be used with DYNASET hydraulic
equipment. Depending on the operating temperature, following mineral hydraulic
oils are recommended:
Mineral hydraulic oil
Operation temperature up to
ISO VG 32S
60 °C
ISO VG 46S
70 °C
ISO VG 68S
80 °C
NOTE!
Recommended oil viscosity is between 10 to 35 cSt when operating at
normal operating temperature.
Содержание HKL 1300
Страница 2: ......
Страница 73: ...DYNASET OY all rights reserved...