![Dynaset GENSCO HMAG PRO 1200-49 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/dynaset/gensco-hmag-pro-1200-49/gensco-hmag-pro-1200-49_user-manual_2548775029.webp)
30
Dynaset Oy | Menotie 3, 33470 Ylöjärvi | puh. 03 3488 200 | [email protected] | www.dynaset.com
HYDRAULIC MAGNETS
MAINTENANCE
6.3. ACCESSING THE GENERATOR
Open either the service hatch or remove the entire magnet’s cover to access the
HMAG PRO’s generator.
The service hatch can be used when checking hydraulic and electric connection
or display’s notifications. For maintenance the cover has to be removed.
REMOVING THE COVER
The HMAG PRO’s cover is held by 12 bolts. To remove the cover follow these
instructions.
1. Set the HMAG PRO on to a steady and flat platform.
2. Disconnect hydraulic hoses from the magnet. Remember to disconnect and plug
the hoses inside the cover!
3. Unscrew the bolts(12).
4. Slowly lift the cover off.
To install the cover follow the instructions in reverse order.
Picture 16: Removing the cover of the HMAG PRO