9.5 Engine control light
The flashing intervals occur only when the engine is at a standstill
and after an ignition switch (starter switch in position "0" and then
back in position "I").
Each flashing interval is repeated three times. There is a pause of
approx. 3 secondsin between.
The control unit saves each detected fault for two operating cycles
(start, run, stop).
If the fault than no longer occurs, it is deleted from the memory and
the corresponding flashing interval no longer occurs.
1.
Evaluate and take note of the flashing interval.
2.
If necessary, evaluate and take note of the further fault
codes.
3.
Perform troubleshooting.
4.
If necessary, contact our Customer Service.
5.
After the troubleshooting, start and switch the engine off
twice.
6.
Then set the starter switch to position "I" (ignition on) and
check whether the fault has been rectified (engine control
light remains off).
Flashing
code
Fault
Possible cause
Remedy
1 x short
No engine oil pressure.
The engine is shut
down.
Engine oil level too low
Check the engine oil level, top
up if necessary
2 x short
Engine temperature is
too high.
The engine is shut
down.
Engine oil level too high
Check the engine oil level;
drain off engine oil if necessary.
Air filter contaminated
Clean the air filter, replace if
necessary.
Lack of cooling air
Clean the cooling fins and the
cooling air intake openings.
Check air guide plates and
ducts for completeness and
good sealing.
Engine oil temperature
is too high.
The engine is shut
down if the engine oil
temperature continues
to rise.
Engine oil level too high
Check the engine oil level;
drain off engine oil if necessary.
Lack of cooling air
Clean the cooling fins and the
cooling air intake openings.
Check air guide plates and
ducts for completeness and
good sealing.
B-695-0093
Fig. 142
Troubleshooting – Engine control light
DRP45DX
114
Содержание DRP45DX
Страница 6: ...Table of contents DRP45DX 6...
Страница 7: ...1 Introduction Introduction DRP45DX 7...
Страница 11: ...2 Technical data Technical data DRP45DX 11...
Страница 15: ...3 Concerning your safety Concerning your safety DRP45DX 15...
Страница 42: ...Concerning your safety Safety Components DRP45DX 42...
Страница 43: ...4 Indicators and control elements Indicators and control elements DRP45DX 43...
Страница 49: ...5 Checks prior to start up Checks prior to start up DRP45DX 49...
Страница 56: ...Checks prior to start up Daily maintenance DRP45DX 56...
Страница 57: ...6 Operation Operation DRP45DX 57...
Страница 65: ...7 Loading transporting the machine Loading transporting the machine DRP45DX 65...
Страница 68: ...Loading transporting the machine Lashing the machine to the transport vehicle DRP45DX 68...
Страница 69: ...8 Maintenance Maintenance DRP45DX 69...
Страница 107: ...9 Troubleshooting Troubleshooting DRP45DX 107...
Страница 120: ...Troubleshooting DCI faults DRP45DX 120...
Страница 121: ...10 Disposal Disposal DRP45DX 121...
Страница 123: ......
Страница 124: ......