34
CC 622/622HF M622EN3
SPECIAL INSTRUCTIONS
Standard oils and other
recommended fluids
Higher ambient temperature
above +50°C (122°F)
The temperature limits apply to standard versions of
the roller.
Rollers that are fitted with additional equipment, such
as noise suppression, etc., may require extra observa-
tion in the higher temperature ranges.
Temperature
High-pressure washing
Never aim a water jet directly at the cap of the
fuel tank or hydraulic reservoir. This is
especially important when using a high-
pressure jet.
Do not spray water directly on electric components or
the instrument panel. Put a plastic bag over the filler
cap of the fuel tank and secure with a rubber band.
This will prevent water from entering the venting hole in
the filler cap. This could otherwise cause operational
disturbance, for example, a clogged filter.
In the event of fire in the machine, use an ABE powder
fire extinguisher if possible. A BE-type carbon dioxide
fire extinguisher may also be used.
If the roller is equipped with a protective structure
(ROPS, Roll Over Protective Structure), or protective
cab, never subject the structure or cab to welding or
drilling. Never attempt to repair a damaged structure or
cab; they must be replaced with new ones.
Fire fighting
When using an auxiliary battery to assist starting,
always connect the positive terminal of the auxiliary
battery to the positive terminal of the roller battery, and
negative to negative.
Protective structure (ROPS),
protective cab
Starting aid
When they leave the factory, the systems and
components are filled with oil or fluid as indicated in the
Lubrication specification and are thus suitable for
operation in ambient temperatures between -10°C and
+40°C (14°F - 104°F).
A maximum temperature of +35°C (95°F)
applies for biological hydraulic fluid.
The following recommendations apply for operation in
higher ambient temperatures up to a maximum of
+50°C (122°F):
The diesel engine can be run at this temperature using
the normal oil, but for other components, the following
fluids must be used: Hydraulic system: mineral fluid
Shell Tellus TX100 or equivalent.