Dynamic SpeedCop 2000 Скачать руководство пользователя страница 1

Dynamic Technology Inc.

www.dynamictek.com

User Manual

FM Wireless Home Security

Alarm System 

-

SpeedCop

TM

2000-

User Manual

FM

Wireless Home Security

Alarm System 

-

Speed

Cop

TM

2000-

Содержание SpeedCop 2000

Страница 1: ...Dynamic Technology Inc www dynamictek com User Manual FM Wireless Home Security Alarm System SpeedCopTM 2000 User Manual FM Wireless Home Security Alarm System SpeedCopTM 2000...

Страница 2: ...and Sensors 10 ARS Structure Main Body PIR Door Sensors 11 Remote Control 25 Input Remote Control Code 26 Remote Controller 13 Guide of emergency meeting 27 Sensors 14 Power Tel Line cut off 28 Telep...

Страница 3: ...munication Distance Max 1000M Detection Range Max 30M Dimension 32D x 97H x 65W Door Sensor Composition 2 Magnetic Bars 1 RF Transmitter Detection Method Magnetic Remote controller Composition 2 Butto...

Страница 4: ...etector RF Module Infrared Detector Modulation Frequency Modulation Frequency Bandwidth 447 275MHz Power DC 9V Application Field Gas Door Fire Detector dimensions PIR Sensor Ceiling style Pet Detector...

Страница 5: ...off the main body can operate itself by DC 9V alkaline battery continuously Power LED changes to a green color and other LED s are off if the main body is supplied with power by the backup battery In...

Страница 6: ...ment 10 Chime Automatic alarm notice is arming if the door is not completely closed and chime bell sound when Disarming mode of the main door sensor 11 911 Emergency call Automatic call to 911 by one...

Страница 7: ...mergency to outside by light 2 External Siren Notice emergency to outside by siren 3 Impact Detector Install at windows for detecting intruder 4 Infrared Detector Installing both sides of intruding ro...

Страница 8: ...r controlling sensors or siren at the main body 8 Common Common terminal of external output terminal A B 9 Output B The second output terminal for controlling sensors or siren at the main body 10 Inpu...

Страница 9: ...the intruder with Siren and arms Option Call to related office or neighbor for help F l o w F l o w C h a r t C h a r t F l o w F l o w C h a r t C h a r t Intruders Sensor 1 Sensor 2 Sensor 7 FM Tran...

Страница 10: ...p t e r 4 I n p u t t h e t e l e p h o n e n u m b e r s s e t u p s e n s o r s a n d r e m o t e 4 I n p u t t h e t e l e p h o n e n u m b e r s s e t u p s e n s o r s a n d r e m o t e control...

Страница 11: ...e C o n n e c t i n g o f S e n s o r s C o n n e c t i n g o f S e n s o r s Gas controller Gas Breaker Siren Other wire sensors Telephone line IN Output1 Output Com Output2 Input 1 Input Com Input 2...

Страница 12: ...000 11 Dynamic Technology Inc Setting up T tag on the wall Hanging the Main body at the three points of the T tag 45 0 1 The position of PIR sensor is suitable opposition side from door or intrusion r...

Страница 13: ...ler 2 Remote controller Setup 1 3 Press the number again The second remote controller is Press the Key 4 Remote Controller Reset Remote Controller Reset Menu Input 11 ARS Comment Key Sensor Reset Sens...

Страница 14: ...ng of User s comment 61 Telephone Number 31 37 Replaying of the user s comment 62 Emergency Call 41 43 Exit 71 Press the arming button 4 Input Completed ARS Comment Input Remote Controller SpeedCopTM...

Страница 15: ...ing or disarming of appointed sensors among installed sensors by user s requirement 2 1 Sensor detecting Set up the sensor No 1 Bypass Input completed ARS Comment Input Sensors SpeedCopTM 2000 14 Dyna...

Страница 16: ...l of 7 telephone number 7806890 5 Please input the first telephone number ex 323 2680 Press the Key 1 SpeedCop 2000 Confirming the first telephone number Confirming Telephone number Confirming Telepho...

Страница 17: ...n that is near where you are Press the Key 911 5 Please input the first emergency call number ex 911 Press the Key 1 SpeedCop 2000 Confirming the first number Confirming the number Confirming the numb...

Страница 18: ...l the main body with remote control from outside by telephone When user wants to B y p a s s When user touch any key on the main body under Arming In this case The main body requests password Input Pa...

Страница 19: ...start recording warning message for 12 seconds Menu Input 6 Menu Input 61 Recording 12 Input Voice Recording SpeedCopTM 2000 18 Dynamic Technology Inc 6 1 1 SpeedCop 2000 Replay of recorded voice Rep...

Страница 20: ...000 Press the number Key 1 Menu Input 7 7 2 Press the number Key Menu Input 71 1 3 Press Key Delay Time 5 Press the Key Input Completed ARS Comment 4 Delay Time 15 Input the interval time you wanted e...

Страница 21: ...ren ON OFF 4 Please press any number key The main body is changed from on off to off on automatically Siren OFF Press the number Key 1 Menu Input 8 8 2 Press the number Key Menu Input 81 1 3 Press the...

Страница 22: ...pleted 2 Telephone No 2 Input completed 3 Telephone No 3 Input completed 4 Telephone No 4 Input completed 5 Telephone No 5 Input completed 6 Telephone No 6 Input completed 7 Telephone No 7 Input compl...

Страница 23: ...ime Out 15 Disarming Disarming Converting from Arming to disarming mode Disarming Completed ARS Comment 1 2 3 4 5 6 7 Aem Power Green LED is flicker 1 2 3 4 5 6 7 Arm Power Only power LED is On in sta...

Страница 24: ...Bypass Function Bypass Function Bypass User select specific sensor and then register at the main body so the specified sensors are armed Dis arming Arming Disarming manual use SpeedCopTM 2000 23 Dyna...

Страница 25: ...ody informs the fact In case third door sensor is opened The Third LED flickers Chime A door is opened ARS Comment Door Sensor 3 Close the door or the window Special Function Bypass Alarm SpeedCopTM 2...

Страница 26: ...g number is 10 disarming number is 20 to end press star key Arming of SpeedCop Repeat twice Enter Password Enter Password Order performance Order performance To listen again press 0 To listen again pr...

Страница 27: ...a l A 60 Output B control Operate wired equipment connected output t e r m i n a l B Ex Gas controller Outdoor siren etc 20 Disarming 40 Output A disarming The siren included in the main body is turn...

Страница 28: ...n off the Gas 70 Emergency Completion Listen to the ARS comment that a intruder is detected and then check whether it is family or intruder Threaten the intruder by siren call the police Listen to the...

Страница 29: ...o u t 6 h o u r s Cutting off of telephone line 1 A r m i n g I n c l u d e s S t a y f u n c t i o n Please connect telephone line ARS Comment 2 S e n s i n g a f t e r a r m i n g R i n g i n g S i...

Страница 30: ...IR sensing function Sensing distance Approx 10M 20M Communication distance about 1Km Detecting Angle Wide angle 110 Vertical angle 45 Automatic notice of low voltage Life cycle of battery 6 months at...

Страница 31: ...6 months Adapter DC 9V available RF transmitter sensors Wire Radio Frequency Transmitter DIP Switch control Dismantle 2 pieces of screw on PCB after opening the rear cover of RF Transmitter Control th...

Страница 32: ...that its features remain effective and that it be updated or replaced if it is found that it does not provide the protection expected Access by Intruders Intruders may enter through an unprotected ac...

Страница 33: ...located on a different level of the residence or premise then it is less likely that the occupants will be alerted or awakened Audible warning devices may be interfered with by other noise sources su...

Отзывы: