   Installation Instructions & Consumer Information 

 

 

       RS4 

Whole House 

IAQ System              

 

 

  RS4 Whole House IAQ System 

  Polarized-Media Electronic Air Cleaner 

  Activated Carbon Matrix System 

 

Series2 Germicidal UV Lamp 

 

 

Note: Read these instructions 
carefully before installation 

 

 
 

Introduction 

 
Your RS4 Whole House IAQ System is a high efficiency air cleaning system designed to remove 
all three types of airborne contaminants: particles, biologicals, and gas phase contaminants.  The 
large surface areas of the air cleaner and activated carbon help to reduce air velocity and static 
pressure resistance for more effective filtration.   
 
    

Section I. Cabinet Installation 
  

1)  Turn the thermostat fan switch to the “OFF” position. 
2)  Turn off power to the furnace/air handler.  
3)  Remove the existing filter from the furnace/air handler or return air grille. 
4)  Locate the RS4 cabinet on the return side of the ductwork, adjacent to and upstream of the 

blower compartment.  This placement will ensure that the furnace blower and cooling coil are 
kept clean.  Determine the mounting orientation in a location that is readily accessible for 
service and maintenance, allowing a minimum of 27” in front of the slide-out access panel. 

5)  If the cabinet is installed on a flat surface, seat the cabinet on vibration pads (1/2” minimum) to 

provide adequate clearance for the door operation. 

6)  When securing the RS4 cabinet into the HVAC system, do so with the cabinet door in place to 

keep the cabinet plumb. This will ensure that the access door fits properly after installation.     

7)  The RS4 cabinet uses interchangeable block-off plates that can be positioned to allow airflow 

through the cabinet at a right-angle or flow-through from side to side or top to bottom.  
Mounting holes are provided in the air cleaner cabinet for #10  sheet metal screws or 1/8” 
rivets.  All system components allow for installation with airflow in any direction. 

8)  The RS4 cabinet includes one set of adjustable duct flanges that can adjusted to connect the 

top/bottom 24”x8”  duct opening to duct sizes of  24’x8”,  24”x9”, 24”x10”, 24”x11”, or 24”x12”. 
The cabinet is shipped with top  flanges  in the 24”x10” center  position.  To adjust the flanges, 
remove the flange screws, adjust the flanges to the desired duct size, and secure with screws.  
Openings on the side of the cabinet measure 23.5” x 13.5”.  Additional duct flange kits for side 
connections (part no. RS4-FLANGEKIT) are available as an optional accessory. 

Содержание RS4

Страница 1: ... and maintenance allowing a minimum of 27 in front of the slide out access panel 5 If the cabinet is installed on a flat surface seat the cabinet on vibration pads 1 2 minimum to provide adequate clearance for the door operation 6 When securing the RS4 cabinet into the HVAC system do so with the cabinet door in place to keep the cabinet plumb This will ensure that the access door fits properly aft...

Страница 2: ...d a grommet is provided for the wiring hole Once the cabinet has been secured seal all seams and holes with foil tape or mastic so that the cabinet is air tight and UV light cannot escape Figure 2 Side View Wire inlet both sides Figure 1 Knock outs for UV Lamp safety switch ...

Страница 3: ...3 Figure 2 Front View Figure 4 Top Bottom View Figure 3 Front View ...

Страница 4: ... found c If continuity is found between one of the terminals and the furnace air handler that terminal will be the Common terminal d With the power on to the transformer use the voltmeter to locate the 24vac terminal If a Common or 24vac terminal cannot be located it will be necessary to install a separate transformer If a hard wired transformer is used an isolated class II transformer is recommen...

Страница 5: ... POSITION Section IV UV Lamp Installation 1 The model 407H 16 or the 407H 16 O3 Series2 Germicidal UV Lamp is standard on some models or available separately 2 Remove the cover from the unit by removing the top and bottom retaining screws using a screwdriver 3 Remove the knock outs on the RS4 cabinet door for UV lamp and safety switch fig 1 4 Attach back of the UV unit to the cabinet door using th...

Страница 6: ...s should be used with your air cleaner Failure to do so could cause damage to the air cleaner alter air cleaner performance and or void your Warranty Replacement media pads are available from your heating and air conditioning contractor CAUTION WHENEVER INSTALLING OR REMOVING THE AIR CLEANER THE POWER TO THE FURNACE AIR HANDLER SHOULD BE TURNED OFF CARE SHOULD BE TAKEN NOT TO LET THE JACK TOUCH AN...

Страница 7: ...en the air cleaner latches carefully remove the old carbon inserts and discard 7 Position the new carbon inserts so that they are centered within the frame fig 7 8 Close and re latch the air cleaner 9 Return the air cleaner to its location in the filter rack 10 Plug the power supply cord into the air cleaner once it is securely in place fig 6 11 Close the cabinet access door and restore power to t...

Страница 8: ... every two 2 years Use only GENUINE replacement parts 2 Replacement parts can be ordered from your heating and air conditioning contractor Have the model number or unit size available when calling Filter Box Parts Item Description 1 Door Assy 2 Door Handle 3 Door Clip 4 Front Frame Assy 5 Door Lock Nut 6 Block off plate 7 Bottom Angle 8 Top Angle 9 Back Cover 10 Flange Assembly Air Cleaner Carbon ...