Chapter 4: Programming the Rhino2
79
4.4.3.8
Minimum Reverse Speed
Parameter
Possible Values Default
HHP Lite
Std Adv
Minimum Reverse Speed
0 - 60 %
20 % (Profile1)
20 % (Profile 2)
This parameter is only used when
(4.4.2.11) is set to 'Yes'.
Sets the maximum speed in the reverse direction when the lowest speed has been selected
with the speed limit pot (see 3.10.6) and the throttle is fully deflected reverse. Dealers can
adjust this parameter to the preference of an individual user or to the terrain that a specific
scooter will be used in.
Note:
This parameter cannot be set lower than the value of the
parameter (4.4.4.4) that has been set by the scooter manufacturer.
4.4.3.9
Soft Start Period
Parameter
Possible Values
Default
HHP
Lite
Std Adv
Soft Start Period
0 - 2550ms
DS90, DS120:
800ms
DS160:
1000ms
Whenever there is a change in speed demand, the soft start function temporarily reduces
the acceleration / decelaration rate during the time that is set with
Soft Start Period
. This
makes the acceleration / decelaration smoother, especially with high acceleration /
decelaration rates or high load compensation settings.
Higher values give a softer start, while lower values give a more direct and harsh start.
To disable soft start completely, set
Soft Start Period
to zero.
Soft-Start Period
Time
Speed