Chapter 4: Programming the Rhino2
77
4.4.3.4
Maximum Reverse Speed
Parameter
Possible Values
Default
HHP
Lite
Std Adv
Maximum Reverse Speed
20 - 100 %
DS90, DS120:
40 % (Profile1)
30 % (Profile 2)
DS160:
35 % (Profile1)
35 % (Profile 2)
Sets the maximum speed in the reverse direction when the highest speed has been selected
with the speed limit pot (see 3.10.6) and the throttle is fully deflected reverse. Dealers can
adjust this parameter to the preference of an individual user or to the terrain that a specific
scooter will be used in.
Note:
This parameter cannot be set higher than the value of the
parameter (4.4.4.2) that has been set by the scooter manufacturer.
4.4.3.5
Reverse Acceleration
Parameter
Possible Values Default
HH
P
Lite
Std Adv
Reverse Acceleration
0 - 100 %
DS90, DS120:
30 % (Profile1)
30 % (Profile 2)
DS160:
15 % (Profile1)
15 % (Profile 2)
Sets how quickly the reverse speed increases after the throttle has been deflected reverse.
0 %
- From standstill, the scooter reaches full reverse speed in 10 s
100 %
- From standstill, the scooter reaches full reverse speed in 0.4 s
Low acceleration values give a softer performance and a less sensitive throttle response. High
acceleration values give a more aggressive performance and a fast throttle response.
Note:
This parameter cannot be set higher than the value of the
parameter (4.4.4.5) that has been set by the scooter manufacturer.