Chapter 4: Programming the Rhino2
69
4.4.2.5
Throttle Response
Parameter
Possible Values
Default
HHP
Lite
Std Adv
Throttle Response
0 - 100 %
80 %
Defines the scooter response to movement of the throttle.
0%
- The response to the throttle is linear. If the throttle is held halfway, the scooter will
drive at half its programmed speed.
100% - The response to the throttle is curved. If the throttle is held halfway, the scooter will
drive at around 25% of its programmed speed. This gives the user finer control at
low speed. The curve does not change the maximum speed, so the scooter will still
drive at full maximum speed when the throttle is fully deflected.
4.4.2.6
Throttle Dead-band
Parameter
Possible Values
Default
HHP
Lite
Std Adv
Throttle Dead-band
0 - 100 %
25 %
Also commonly referred to as 'Neutral Window',
Throttle Dead-band
sets how far the throttle
must be moved out of neutral before the controller will begin to drive.
The percentage range is dependent on the value of the
parameter (4.4.2.1).
Wig-wag and Uni-polar:
0% = 2.5V +
(4.4.2.3), 100% =
Throttle Full Scale Deflection
Single-ended:
0%
=
Minimum Throttle Voltage
100% = (
Maximum Throttle Voltage -
0%)/2 + 0% (halfway between 0% value and
Max V
)
Speed
Movement
100%
100%
50%
0%
100%
5 V
0 V
NO
0 - 100% DB
Max V
Fault
Full
Speed
Throttle Dead Band range for Wig-wag and Uni-polar setups
0 - 100 % DB
FSD
FSD
Min V
2.5
Full
Speed
Fault
5 V
0 V
NOx2
0 - 100% DB
Max V
Fault
Throttle Dead Band range for Single-ended setups
FSD
Min V
Fault
Halfway valid range = 100%