background image

DYNAMIC ENGINEERING 

150 DuBois St. Suite B/C Santa Cruz CA 95060 

831-457-8891 

 

https://www.dyneng.com

 

[email protected]

 

 Est. 1988 

 

User Manual

 

cPCIBPMC6U 

 

 

cPCI 6U 4HP 2 Position PMC Compatible Carrier

 

 

Previous model with shown

 

 

Manual Revision 10p1 6/9/22 

Corresponding Hardware: Revision 10 

Fab number: 10-2006-0710 

Содержание cPCIBPMC6U

Страница 1: ...z CA 95060 831 457 8891 https www dyneng com sales dyneng com Est 1988 User Manual cPCIBPMC6U cPCI 6U 4HP 2 Position PMC Compatible Carrier Previous model with shown Manual Revision 10p1 6 9 22 Corres...

Страница 2: ...product described in this document at any time and without notice Furthermore Dynamic Engineering assumes no liability arising out of the application or use of the device described herein The electron...

Страница 3: ...ions 8 PMC Position 0 Rear Panel IO Interface Pin Assignment 9 PMC Position 1 Rear Panel IO Interface Pin Assignment 10 APPLICATIONS GUIDE 11 Interfacing 11 Construction and Reliability 12 Thermal Con...

Страница 4: ...Embedded Solutions Page 4 FIGURE 1 CPCIBPMC6U POSITION O PN4 INTERFACE STANDARD 9 FIGURE 2 CPCIBPMC6U POSITION 1 PN4 INTERFACE STANDARD 10...

Страница 5: ...nd 5V planes more than 10A each plus 1A on the 12V connections Special features Universal cPCI 6U 4HP Extended temperature range 40 85C components LED names within quotes visible on bezel LED on PMC B...

Страница 6: ...itch 2 SM66EN signal is also routed to the PMC connector pin M66EN If the PMC uses the M66EN as an input the dipswitch can be used to control the frequency If the PMC uses the M66EN pin as a control t...

Страница 7: ...ting is controlled impedance and matched length Routed as differential parts with 100 ohm impedance for each pair Fans can be added where high power PMCs are used or inadequate in chassis circulation...

Страница 8: ...esign is versatile with PCI 32 PCI 64 rear IO versions and a slot zero configuration cPCIBPMC3U32 is bridged isolating the PMC from the cPCI bus cPCI connections are specification compliant on cPCIBPM...

Страница 9: ...4 2 8 P M C _ 0 _ I O 2 9 J 3 B 8 J 1 4 2 9 P M C _ 0 _ I O 3 0 J 3 A 8 J 1 4 3 0 P M C _ 0 _ I O 3 1 J 3 E 7 J 1 4 3 1 P M C _ 0 _ I O 3 2 J 3 D 7 J 1 4 3 2 P M C _ 0 _ I O 3 3 J 3 C 7 J 1 4 3 3 P M...

Страница 10: ...2 9 P M C _ 1 _ I O 3 0 J 5 A 8 J 2 4 3 0 P M C _ 1 _ I O 3 1 J 5 E 7 J 2 4 3 1 P M C _ 1 _ I O 3 2 J 5 D 7 J 2 4 3 2 P M C _ 1 _ I O 3 3 J 5 C 7 J 2 4 3 3 P M C _ 1 _ I O 3 4 J 5 B 7 J 2 4 3 4 P M C...

Страница 11: ...mounting locations per PMC Two into the PMC mounting bezel and two for the standoffs near the PMC bus connectors Start up A third party PCI device cataloging tool will be helpful to check that the Ve...

Страница 12: ...pin 100 insertion cycles minimum These connectors make consistent correct insertion easy and reliable The PMC Module is secured against the carrier with the PMC connectors It is recommended for enhan...

Страница 13: ...ir charges must accompany the return Dynamic Engineering will not be responsible for damages due to improper packaging of returned items For service on Dynamic Engineering Products not purchased direc...

Страница 14: ...ates Software Interface transparent Bridge Initialization Selections for VIO primary and secondary clock rates Interface PMC front bezel via cPCI bracket Rear IO option Dimensions 6U 4HP Construction...

Страница 15: ...e mounted PMC 5 CFM Zero Slot type Mounted in reverse to pull air from the PMC side and blow to the rear FAN 1 2 R Add a fan to cool the mounted PMC 8 CFM full height fan will interfere with next cPCI...

Отзывы: