ultra
D
Water Meter
Manual
Dynaflox Shanghai Co., Ltd.
03/2016
Страница 1: ...ultraD Water Meter Manual Dynaflox Shanghai Co Ltd 03 2016 ...
Страница 2: ...ition 5 4 Display Description 6 4 1 Digital Display DN15 25 6 4 2 Digital Display DN32 300 6 5 Modbus Communication Protocol 7 5 1 Modbus RTU Protocol Introduction 7 5 2 Modbus RTU Protocol Message Frame 7 5 3 Register List 8 6 Handheld Operator Description 11 7 Replace Battery 12 8 Troubleshooting and sales commitments 13 8 1 Common Troubleshooting 13 8 2 Warranty 13 ...
Страница 3: ...xpanded pipe bends or other flow disturbers please select other installation location or rectify the pipeline If you need the meter without installation requirement of straight pipe please contact the factory 3 The preferred installation location is horizontal pipe followed by the vertical pipe with upward or obliquely upward flow avoiding the downward or obliquely downward flow to prevent the par...
Страница 4: ...agnetic Environment Class E2 Flow Profile Sensitivity U3 D0 Display 9 digit LCD Display prompts Cumulative flow m3 Instantaneous flow m3 h Flow direction Alarm Battery level Output mode etc Connections Threads DN15 40 Flanges DN50 300 according to DIN EN1092 1 Other standards customizable Date Storage Store the data in last 7 24h 365 days and 72 months Output optional RS485 ModBus M Bus OCT pulse ...
Страница 5: ...Meter Size mm 15 20 25 32 40 inch 1 2 3 4 1 1 1 4 1 1 2 L Length mm 165 195 225 260 300 B Width mm 100 100 100 90 130 H Height mm 83 83 83 130 132 H1 Height mm 166 166 166 226 225 h Height mm 22 22 22 19 20 L1 Length mm 260 290 345 385 430 Weight kg SS 1 0 1 2 1 4 4 8 6 5 Brass 0 14 0 52 0 81 1 57 3 39 ...
Страница 6: ...80 185 213 226 231 280 327 374 5 414 5 h Height mm 65 68 93 102 112 142 5 170 197 5 222 5 d x n 18x4 18x4 18x4 18x4 18x4 22x8 22x8 22x12 22x12 K mm 125 145 160 180 210 240 295 355 410 Pressure MPa 1 6 1 6 1 6 1 6 1 6 1 6 1 1 1 Weight kg SS 9 11 13 16 21 29 46 60 74 Cast Iron 6 6 5 13 16 21 30 45 55 68 Remarks d diameter of bolt holes n numbers of bolt holes K central circle diameter of bolt holes ...
Страница 7: ...llation C Recommendations for achieving top performance 3 pipe diameters before and after elbows 90 o Minimum of 6 pipe diameters before and after Minimum of 10 pipe diameters after pumps Minimum of 6 pipe diameters before T connections Minimum of 6 pipe diameters after strainers 3 pipe diameters before and after elbows 90 o in vertical installations ...
Страница 8: ...ital display contents are as follows 4 1 Digital Display DN15 25 LCD display The switch between different screens is achieved by the light button The light button can work normally when the light intensity meet the requirement When it s dark a lamp can be used to illuminate the light button 4 2 Digital Display DN32 300 Leak detection Battery Serial number IR Communication Time Communication Status...
Страница 9: ...RTU protocol Baud rate 1200 2400 4800 9600 optional Character type 8 data bits no parity bit 1 stop bit 5 2 Modbus RTU Protocol Message Frame Start Bit Address Code Function Code Data Area CRC Code Terminator 4 characters time 1 byte 1 byte 2 bytes register address 2 bytes number of register 16 digital 4 characters time Start Bit under RTU mode messages start to send by interval time of 4 characte...
Страница 10: ...etection code Low byte is in front of high byte Terminator after the transfer of the last character the pause time of 4 character marks the end of the message 5 3 Register List Baud rate 1200 2400 4800 9600 Parity bit None Stop bit 1 Data bit 8 Address Length Data Type Data Content Unit Remark 0 2 long Instantaneous flowrate L h 2 2 long Positive cumulative flow integer part m3 4 2 long Positive c...
Страница 11: ...al part mL 0xA010 2 long Negative cumulative flow integer part m3 0xA012 2 long Negative cumulative flow decimal part mL Historical data per day 0xB000 2 long Time 0xB002 2 long Positive cumulative flow integer part m3 0xB004 2 long Positive cumulative flow decimal part mL 0xB006 2 long Negative cumulative flow integer part m3 0xB008 2 long Negative cumulative flow decimal part mL 0xB00A 2 long Ti...
Страница 12: ...ulative flow decimal part mL 0xC00A 2 long Time 0xC00C 2 long Positive cumulative flow integer part m3 0xC00E 2 long Positive cumulative flow decimal part mL 0xC010 2 long Negative cumulative flow integer part m3 0xC012 2 long Negative cumulative flow decimal part mL Definition of error code 10 Sound wave receiving timeout Check whether blank pipe or bubbles in water 01 Velocity out of range 02 Wa...
Страница 13: ...version MBUS pulse display units and current etc The relevant operating instructions of infrared handheld operator refer to infrared handheld operator manual For customers who need to order infrared handheld operator please specially note when ordering the meters Note the following information when using infrared handheld operator 1 The infrared handheld operator must be used within 0 5m from the ...
Страница 14: ...please see our handheld operator manual 7 Replace Battery This product uses 3 6V lithium battery and the battery can be used for more than 10 years When battery voltage is low the screen will display the symbol indicating that the user needs to replace the battery ...
Страница 15: ...ny Innovation and Integrity respect the interests of our customers we solemnly promise to you 1 From the date of delivery meters enjoy one year free warranty 2 If user demands the company will appoint professional technician to help users solve the problem at the first time 3 Dynaflox will not be responsible for and will have no obligation under the Warranty to the following situations 1 Damage ca...
Страница 16: ...r Meter Manual NivoTech www nivotech dk Dynaflox Shanghai Co Ltd www dynaflox com The Company reserves the right to modify the information of the products It is subject to change without notice Publication Date June 2015 ...