TGX Amplifier System Rack
Connector panel CP34 | en
17
Bosch Security Systems, Inc.
Installation manual
2019-03 | 02 | F.01U.346.534
Figure
6.4: Power cabling, top to bottom phase L1, L2, L3, respect. X, Y, Z
The amplifiers are connected to the power outlets of the PD32-EU / PD30-US for an optimized
power input of the amplifiers.
For more information, refer to the PD32/PD30 Mains Power Distributer manual.
6.2
System wiring
The SRTGX racks are designed for an easy set-up of larger systems that contain multiple
system racks by daisy-chaining audio signal and remote control data.
Figure
6.5: Daisy-chain of multiple system racks in a larger system
An advantage of the OMNEO network protocol is the combination of Dante audio and OCA
remote control data in once network cable. Using the primary and secondary line the system
has full redundancy for audio (glitch-free) as well as remote control and supervision with
simply daisy-chaining two network cables between the system racks. It is highly recommended
to always use that built-in redundancy and run redundant cabling for a reliable performance.