background image

 

 

 

 

Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
www.dynacord.com
© Bosch Sicherheitssysteme GmbH, 2014

 

 

 

Содержание PM 502

Страница 1: ...PM 502 en User manual...

Страница 2: ......

Страница 3: ...Phantom power 16 6 2 100 V Direct Drive 16 6 3 Amplifier routing 16 6 4 Speaker processing LPN 17 6 5 AUX mode 17 6 6 Locking 18 6 7 Microphone processing TALK OVER 19 7 Operation 20 7 1 Mono input 2...

Страница 4: ...not fit your mains socket please contact your electrician 10 Ensure that it is not possible to stand on the mains cable Take precautions to ensure the mains cable cannot become crushed particularly ne...

Страница 5: ...ust be used during any work for which the opened device is connected to and operated with mains voltage 3 The device must be free of any voltage before performing any alterations with upgrade sets swi...

Страница 6: ...r environmentally compatible recycling in accordance with the European Waste Electrical and Electronic Equipment Directive To dispose of old electrical or electronic devices you should use the return...

Страница 7: ...ns in this document and the safety notes starting on page 4 before you plug your PM 502 into a power outlet Shipping contents and warranty Quantity Component 1 PM 502 1 Power cord 1 User manual 1 Impo...

Страница 8: ...System overview Front view Rear view 3 8 en System overview PM 502 15 May 14 02 F01U297804 User manual Bosch Sicherheitssysteme GmbH...

Страница 9: ...ore using the PM 502 Do not remove any knobs from the front panel the foil can be easily removed without having to detach the knobs on the control surface Before connecting to the mains supply please...

Страница 10: ...s can also be established through monaural or stereo jacks assigned according to the the illustrations in section Pin assignments page 43 If the device that you want to connect has a balanced output s...

Страница 11: ...of connection is less sensitive to the introduction of external noise or HF interference If you want to connect a monaural sound source to a stereo input channel use the L MONO input The signal is rou...

Страница 12: ...speakers can be connected via speakON or Euroblock connectors High Z speakers shall be connected via the Euroblock connectors only please refer to the following sections speakON The PM 502 is equippe...

Страница 13: ...ion of low impedance speakers Euroblock connector in high Z mode When the Direct Drive mode is activated use pin of CH 1 and pin of CH 2 to connect the 100 V loudspeaker line see following illustratio...

Страница 14: ...MASTER B L R The MASTER B L R outputs the L R master audio signal is present that can be used for additional monitoring side fill and additional zone applications or for the connection of a delay line...

Страница 15: ...e to the USB port on the front panel to use the integrated audio player of the PM 502 The external memory is scanned automatically for suitable audio tracks MP3 or WAV If audio tracks are detected the...

Страница 16: ...aker lines Next to 100 V loudspeaker lines it is possible to drive 70 V loudspeaker lines In this case the limiter of the channel selected for Amp Routing e g MASTER A has to be set to 3 dBu in the OU...

Страница 17: ...setting The following table describes the available LPN filter settings Setting SPEAKER PROCESSING indicator Description HIGH ON In setting HIGH the LPN filter is activated this setting is recommended...

Страница 18: ...pped post MASTER A volume control and therefore affected by the MASTER A control s setting Table 6 3 AUX modes Locking The PM 502 allows locking certain features or parameter settings in the menu A fo...

Страница 19: ...STEREO signal automatically returns to its preset level Please refer to section Menu page 26 how to edit the TALK OVER settings The following diagrams illustrate the available presets The parameters o...

Страница 20: ...he left lowers attenuates the signal of that specific frequency band Before you begin to alter the sound all EQ controls should be set to their neutral position i e their marker points straight up loc...

Страница 21: ...wn Keeping an eye on the indicator during a performance is also a good idea because some changes in the bands dynamics or even a change in keyboard settings can easily lead to channel clipping resulti...

Страница 22: ...post VOLUME control so that the volume setting also influences the amount of the signal that is fed to the FX unit Using the FX controls lets you easily assign an effect for groups of musical instrum...

Страница 23: ...PK indicator This indicates to the user that the internal FX unit is on the verge of clipping e g at a level of 6 dB below the risk of overdrive To achieve an adequate signal to noise ratio please adj...

Страница 24: ...sk of the degradation of your speaker output In that case the volume level has to be reduced The limiter threshold can be edited in the OUTPUT SETTINGS menu please refer to section Menu page 26 Below...

Страница 25: ...preferences or to optimally match it to the acoustic conditions of different locations Independent graphic equalizers for MASTER A MASTER B or AUX each adjustable via hardware controls or the rotary e...

Страница 26: ...e equalizer setting of the channel is not set to flat LIM The threshold of the output limiter has been edited Speaker icon Indicates the Amp Routing If a Dual Amp Routing is selected speakers for outp...

Страница 27: ...80 Hz or 150 Hz are attenuated COMPRESSOR PRESET Soft Hard COMPRESSOR THRESHOLD The range depends on the selected compressor preset COMPRESSOR TYPE 2 1 Ratio 4 1 Ratio Limiter Uplift Soft COMPRESSOR A...

Страница 28: ...signal is not changed and outputted in stereo When Mono is selected the MASTER A L R signal is summed and outputted in mono at MASTER A L and also MASTER A R MASTER B Pre Post Mono Stereo When MASTER...

Страница 29: ...allation location Screensaver Off 60 Min default Off Personalize After the time set here the screensaver is activated You can personalize the device name shown in the screensaver screen DEVICE SETUP 2...

Страница 30: ...e of degradation in the output sound In that case the MASTER or AUX level has to be reduced The LIMIT LED also lights up if the output level is reduced because of high amplifier temperature or too hig...

Страница 31: ...Headphone page 15 Caution Make sure to set the PHONES VOLUME control to its minimum position before connecting headphones Permanent hearing loss may occur if headphones are used at high volume 7 10 PM...

Страница 32: ...Maintenance The PM 502 does not require any maintenance 8 32 en Maintenance PM 502 15 May 14 02 F01U297804 User manual Bosch Sicherheitssysteme GmbH...

Страница 33: ...er 20 20000 Hz THD 0 5 one channel loaded into 4 400 W into 8 240 W Max output power Direct Drive mode bridge configuration continuous 1 kHz THD 1 into 12 680 W Max output voltage power amplifier 1 kH...

Страница 34: ...dBu Mono line inputs GAIN at min position 30 dBu Stereo line inputs 26 dBu PHONES output 21 dBu MASTER A B AUX outputs 11 dBu Input impedances MIC 2 k CD 10 k All other inputs 15 k Output impedances...

Страница 35: ...ctory presets user editable Remote control Footswitch Display 128 x 64 pixels LCD Audio player USB at front panel Switching mode power supply C controlled FAT 32 Supported audio file formats MP3 WAV I...

Страница 36: ...ct dimensions Width x Height x Depth 395 x 244 x 241 mm Rack mount 483 x 223 x 310 3 mm 7 HU Net weight 4 9 kg Shipping weight 6 4 kg Table 9 1 Device in rated condition MIC GAIN 15 dB STEREO GAIN LO...

Страница 37: ...Dimensions 9 1 PM 502 Technical data en 37 Bosch Sicherheitssysteme GmbH User manual 15 May 14 02 F01U297804...

Страница 38: ...NO MASTER B AUX DELAY PRE POST A AUX LIMITER LIMITER LIMITER MASTER A MASTER B L L R R AUX OUT LO CUT LPN LIMITER PROTECT ROUTING CH1 CH2 MUTE AMP PROTECT AMP LIMIT SPEAKER PROC DIRECT DRIVE 20dB LO H...

Страница 39: ...r output channel low Z mode Powered speakers and subwoofers are connected to MASTER B or AUX OUT Signal sources are connected via mic line level inputs and USB Additionally an USB stick is connected f...

Страница 40: ...akers e g D 8A as side room PA are connected to MASTER B Powered monitor speakers e g AXM 12A are connected to AUX OUT Signal sources are connected via mic line level inputs Additionally an USB stick...

Страница 41: ...four TS 100 speakers is connected to MASTER A output set to Mono A PCL power amplifier driving four DL 800 horns is connected to MASTER B set to Mono Signal sources are connected via mic line level i...

Страница 42: ...PowerSub 312 driving six TS 100 speakers is connected to MASTER A output A PCL power amplifier driving another 100 V speaker line zone 2 with ceiling speakers is connected to MASTER B set to Mono As s...

Страница 43: ...SHIELD COLD HOT Figure 10 2 Balanced assignment of stereo jack Figure 10 3 Pin assignment of XLR microphone input with phantom power Figure 10 4 Pin assignment of speaker output CH 1 2 low Z speakON 1...

Страница 44: ......

Страница 45: ......

Страница 46: ......

Страница 47: ......

Страница 48: ...Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany www dynacord com Bosch Sicherheitssysteme GmbH 2014...

Отзывы: