7.0 GROUNDING INSTRUCTIONS
This vacuum cleaner must be properly grounded. If it should malfunction or breakdown,
grounding provides a path of least resistance for electric current to prevent the build-up static
electrical charge and to ensure that static electricity is discharged to ground. The build-up of
static electricity could create a sparking hazard and an ignition hazard.
It is the responsibility of the user to ensure that the compressed air supply outlet is grounded.
Test the electrical continuity of the vacuum cleaner system prior use. (See section “Testing for
ground continuity”).
U
WARNING:
U
This vacuum cleaner system is equipped with conductive wheels, which
allow for the vacuum cleaner system to be grounded with the floor. Do
not substitute the conductive wheels and use only replacement
conductive wheels supplied by the manufacturer.
U
WARNING:
U
To effectively dissipate static electricity and to ensure spark-free
operation, this vacuum cleaner system must be grounded during use.
U
DANGER:
U
Do not operate vacuum cleaner if the air supply outlet is not properly
grounded or if the grounding is questionable.