Maintenance Manual (960-948)
2-15
Troubleshooting Procedures
2.7.2 Procedure 2 Connector Check and Replacement Check
The connection of cable and board may be disconnected or faulty.
Disassemble the computer following the steps described in Chapter 4,
, and perform the following checks:
Check 1
Make sure keyboard cable is firmly connected to CN3240 and
CN3270 on the system board.
If the connection is loose, reconnect firmly and repeat Procedure
1. If the problem still occurs, go to Check 2.
Check 2
System board may be faulty. Replace it with a new one following
the instructions in Chapter 4,
. If the
problem still occurs, perform Check 3.
Check 3
Keyboard may be faulty. Replace it with a new one following the
.
2.8 Touch Pad (Click Pad) Troubleshooting
To check if the computer’s Touch Pad (Click Pad) is malfunctioning or not,
follow the troubleshooting procedures below as instructed.
Procedure 1: Diagnostic Test Program Execution Check
Procedure 2: Connector Check
Procedure 3: Replacement Check
2.8.1 Procedure 1 Diagnostic Test Program Execution Check
Execute the Keyboard test, pressed key display test and Touch pad test in
the Diagnostic Program. Refer to Chapter 3,
, for
more information on how to perform the test program.
If an error occurs, go to Procedure 2. If an error does not occur, touch pad
is functioning properly.
Keyboard
<System board>
CN3240
CN3270
Keyboard I/F
Keyboard B/L I/F
Exchange the system board first as the INSU KB attached to KB and the
used KB is impossible to reuse.
Содержание Portege X30L-K Series
Страница 1: ...Maintenance Manual PORTEGE X30L K Series File Number 960 948...
Страница 74: ...Maintenance Manual 960 948 3 22 Tests and Diagnostics Security menu screen Power Management menu screen...
Страница 75: ...Maintenance Manual 960 948 3 23 Tests and Diagnostics Advanced menu screen Boot menu screen...
Страница 130: ...Maintenance Manual 960 948 D 2 Key Layout D 3 Japan JP Keyboard Figure D 3 JP keyboard...