Model 380 Control Valve
(8 Inch Only)
Dyna-Flo Control Valve Services Ltd.
Phone: 780
•
469
•
4000 Toll Free: 1
•
866
•
396
•
2356 Fax: 780
•
469
•
4035 Website: www.dyna
fl
o.com
P-388M0319A
3
Operation, Parts, and Instruction Manual
SPECIFICATIONS
Confi gurations
Refer to Table 1 of the Sales Bulletin.
Consult your Dyna-Flo sales of
fi
ce for other available
con
fi
gurations.
Sizes and End Connection Styles
Models 380 & 381
Size: 8”
Rating: ASME 900 & 1500
Connections: RF / RTJ / BWE
Maximum Inlet Temperatures and Pressures
In accordance with ASME B16.34 Class 1500 unless limited
by material selection shown in Tables 4 to 7, and Figure 9
of the Sales Bulletin.
Maximum Pressure Drops
Same as maximum inlet pressure unless limited by speci
fi
c
trim construction. For valve assembly shut off pressure drops
refer to Table 8 and Figure 9 of the Sales Bulletin.
Shutoff Classifi cations
Refer to Table 1 of the Sales Bulletin.
Dimensions
Valve
Dimensions
Refer to Table 3 and Figure 2 of the Sales Bulletin.
Approximate Valve Body Weights
Refer to Table 2 of the Sales Bulletin.
Valve Body to Bonnet Bolting
Refer to Table 5 of the Sales Bulletin.
Characteristics
•
Equal Percentage (Standard)
•
Modi
fi
ed Equal Percentage
•
Linear
•
Contact factory for Low-Noise and Anti-Cavitation options.
Flow Direction
Flow down through seat ring except when using Low-Noise
trim.
Packing Type and Examples
The standard packing is PTFE V-Ring. Live loaded low
emission, graphite and other packing arrangements are
also available. Refer to Figure 8.
Flow Coeffi cients
For standard coef
fi
cients at maximum travel, refer to Table 7
of the Sales Bulletin.
For full list of coef
fi
cients refer to document P-CVSM.
Valve Travel
Refer to Table 7 of the Sales Bulletin.
Trim Materials
Refer to Table 6 of the Sales Bulletin.
Materials
Body and bonnet material options include:
LCC (A350-LF2 optional* bonnet material)
WCC (A350-LF2 optional* bonnet material)
CF8M (A182-F316 optional* bonnet material)
*NOTE:
Dyna-Flo reserves the right to substitute a cast
material with the forged bar equivalent in the event a casting
is not available.
Refer to Figure 8 of the Sales Bulletin. Refer to Tables 4 & 5
of the Sales Bulletin for typical construction materials. Refer
to Table 6 of the Sales Bulletin for trim selections.
For more information and other options contact your Dyna-Flo
sales of
fi
ce.