Dyna-Glo RMC-FA100A Скачать руководство пользователя страница 1

PROPANE CONSTRUCTION HEATER

USER’S INSTRUCTION MANUAL

RMC-FA40DLX (40,000 BTU/HR, FORCED - AIR)
RMC-FA100DLX (70,000/100,000 BTU/HR, FORCED - AIR)
RMC-FA150DLX (120,000/150,000 BTU/HR, FORCED - AIR)

RMC-FA40A (40,000 BTU/HR, FORCED - AIR)
RMC-FA50A (30,000/50,000 BTU/HR, FORCED - AIR)
RMC-FA100A (70,000/100,000 BTU/HR, FORCED - AIR)
RMC-FA150A (120,000/150,000 BTU/HR, FORCED - AIR)

F

GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTION PROVIDED
WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND 
PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EXPLOSION, BURN,
ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRIC SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS
SHOULD USE OR SERVICE THIS HEATER.

IF YOU  NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN 
INSTRUCTION MANUAL, LADLES, ETC. CONTACT THE MANUFACTURER.

F

RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE

Dyna-Glo

Delux

MODELS

:

Dyna-Glo

MODELS

:

CSA 2.14-2000, ANSI Z83.7-2000

5/05 Rev.1

 

Содержание RMC-FA100A

Страница 1: ...RE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTION PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBO...

Страница 2: ...Storage 9 Wiring Diagrams 10 Troubleshooting 11 Replacement Parts List 12 Warranty Information FWARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PA...

Страница 3: ...fficiency but still produces a small amount of carbon monoxide Humans can tolerate small amounts of carbon monoxide for short periods Carbon monoxide can build up in a heated space and failure to prov...

Страница 4: ...the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA NFPA 58 and the Natural Gas and Propane Installation Code CSA B149 1 The minimum and maximum inlet pressures to the regulator from the g...

Страница 5: ...00lb 10 F 2 20lb Use Larger Tank Use Larger Tank 20 F 1 100lb Use Larger Tank Use Larger Tank See the parts list for your model of heater to get the specified regulator assembly The propane LP gas tan...

Страница 6: ...liquid dish soap and water to gas joints Bubbles forming show a leak that must be corrected 6 Close propane LP supply valve before attempting to repair connection WARNING Purging and filling of LP gas...

Страница 7: ...at all times The hose assembly should be visually inspected prior to each use of the heater If it is evident that there is excessive abrasion or wear or the hose is cut it must be replaced prior to th...

Страница 8: ...hen the tank is disconnected from the heater MAINTENANCE INSTRUCTIONS 1 Turn unit off allow heater to fully cool and disconnect propane hose before performing any Maintenance functions 2 Keep unit cle...

Страница 9: ...Page 8 PROPANE CONSTRUCTION HEATER ILLUSTRATED 40 000 BTU Hr 50 000 BTU Hr...

Страница 10: ...R 1 CFM40 02 03 17 VALVE 1 CK 890SL A1 A 17 1 VALVE KNOB 1 CFM40 11 18 SCREW 4 ST3 9X8 19 BASEASSEMBLY 1 CFM40 02 20 SCREW 4 ST4 2X10 21 WING BOLT 1 CFM40 M6X12 22 SCREW 1 ST4 2X10 23 HEIGHT CONTROLLE...

Страница 11: ...Page 10 PROPANE CONSTRUCTION HEATER ILLUSTRATED 100 000 BTU Hr 150 000 BTU Hr...

Страница 12: ...1 4A0304 4A0304 19 CONNECTOR INLET 1 4A0234 4A0234 20 VALVE KNOB 1 3D00279 3D00279 21 SCREW 4 BT1408W BT1408W 22 BASEASSEMBLY 1 1A0090 1A0090 23 SCREW 6 BT1408B BT1408B 24 HEIGHTADJUSTER KNOB 1 4TH003...

Страница 13: ...Page 12 WIRING DIAGRAMS...

Страница 14: ...aused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL...