Dyna-Glo RMC- 55R7 Скачать руководство пользователя страница 1

PORTABLE

KEROSENE-HEATER

“OWNER’S  MANUAL”

Before the first use of this heater, please read this OWNER'S MANUAL very

carefully. This OWNER'S MANUAL has been designed to instruct you as to the

proper manner in which to assemble the heater maintain the heater, store the

heater, and most importantly, how to operate the heater in a safe and efficient

manner.  Please keep this manual for future reference.

GHP Group, Inc.,

TELEPHONE : 1-877-447-4768

MODEL : RMC- 55R7 / RMC- 55R7B

4221-0005-11

05/13   Rev. 07

Niles, IL 60714-3302, USA

Содержание RMC- 55R7

Страница 1: ...esigned to instruct you as to the proper manner in which to assemble the heater maintain the heater store the heater and most importantly how to operate the heater in a safe and efficient manner Pleas...

Страница 2: ...sport or store kerosene or any other flammable liquids Occasionally during normal operation you will hear the sound of fuel draining from the cartridge tank to fill the fuel reservoir area This is nor...

Страница 3: ...THE HEATER WICK MAINTENANCE CARBON REMOVAL DRY BURNING ITEM WICK REPLACEMENT CHECKING THE IGNITION SYSTEM WICK ADJUSTER MECHANISM AUTOMATIC SAFETY SHUT OFF DEVICE LONG TERM STORAGE OF YOUR HEATER SPEC...

Страница 4: ...er who stores it in a large underground or above ground tank Kerosene that is contaminated with even a small amount of water will prevent a kerosene heater from functioning properly As you move from t...

Страница 5: ...ith this heater according to the plus and minus markings inside of the holder Remove dead batteries at once and dispose of them properly Remove batteries when not in use or when heater is being stored...

Страница 6: ...sene container Make sure that you securely replace the fuel tank cap on the cartridge tank and on the kerosene container Thoroughly clean up any spilled kerosene Insert the cartridge tank back into th...

Страница 7: ...eries it is possible to light the heater with a match Fig 7 The procedure is as follows Turn the wick adjuster knob clockwise until the wick has been raised to its maximum height Lift the burn chamber...

Страница 8: ...juster knob to keep the proper flame height It is recommended that the heater be checked every 30 minutes in order to keep the proper adjustment because periodic adjustment is required FAILURE TO KEEP...

Страница 9: ...rm the following check and maintenance procedure on a daily basis during the heating season WARNING In performing the check and maintenance procedure NEVER ATTEMPT TO REPAIR THE FOLLOWING PARTS Automa...

Страница 10: ...th an old tooth brush or other stiff bristle brush to remove any remaining ash A canister type vacuum cleaner may be a useful tool in removing this ash Step 2 The first step should remove most carbon...

Страница 11: ...e center loosening it from the sharp metal teeth on the inner surface of the holder and slide it out Remove the wind cover Remove the automatic ignition Assembly by unscrewing 2 screws 6 p e t S 5 p e...

Страница 12: ...e adjuster shaft to the front of the heater Snug 4 wing nuts on the mounting stud but do not tighten Raise the wick to the full up position and evently tighten wing nuts in several steps Check height...

Страница 13: ...saturate with kerosene Reinstall the wind cover Remove the wick adjusting knob once again if it was reinstalled before Reinstall the cabinet Tighten 5 screws on the cabinet Reinstall the chimney and t...

Страница 14: ...rosene odor when extinguishing the heater AUTOMATIC SAFETY SHUT OFF DEVICE This heater is equipped with an automatic safety shut off device The purpose of this device is to quickly and efficiently shu...

Страница 15: ...thorough cleaning reassemble the heater It is important when reassembling the wick adjuster to be sure to maintain an equal gap between the wick adjuster and the wick guide cylinder all around See Wic...

Страница 16: ...oxygen in the room that it is being used it can cause improper combustion and can generate carbon monoxide Never use heater in areas where flammeable vapors or gases may be present Never use the heate...

Страница 17: ...Perform Carbon Removal Dry Burning procedure Replace wick if necessary 5 Contaminated kerosene 5 Drain tank Remove wick assembly replace wick Reinstall wick assembly Fill tank with water clear 1 K ker...

Страница 18: ...WS CT19R WS CT20R WS CT21R See 24 See 24 1 WS CT23R 1 2123 0030 00 24 1 WICK ADJUSTER RMC 55R7B COMPLETE 2123 0031 00 25 25 1 26 27 28 29 30 31 32 33 34 WICK ADJUSTER KNOB RMC 55R7 WICK ADJUSTER KNOB...

Страница 19: ......

Страница 20: ...GHP Group Inc 6440 W Howard St Niles IL 60714 3302 Tel 877 447 4768 www ghpgroupinc com GHP Group Inc 6440 W Howard St Niles IL 60714 3302...

Отзывы: