Integrated Cooling System
–
After the lamp is turned off, there is a 5-minute time off delay on the irradiator cooling fans. Do not turn
off main power to the system until this 5-minute delay has elapsed. Failure to wait can cause damage to the irradiator cooling
assembly or the UV lamp.
UV Blower
–
The UV blower removes heat and ozone produced by the UV bulb. A
6”
-round duct for the UV blower exhaust is
provided on the top of the curing system. Additional ducting should be added to vent the exhaust outside of your building. You may
need to add an additional blower to your system depending upon the length and configuration of your exhaust ducting.
UV-Resistant Belt
–
Belt speeds can be adjusted from 4-30 feet per minute.
UV-Light Shielding
–
The shielding prevents operators from exposure to stray UV light.
Ventilation System
–
T
he system’s i
ntegral vacuum hold-down ventilation system keeps parts securely on the conveyor belt. The
ventilation system has an external exhaust duct that can be attached to standard exhaust ducting. Exhausting the blower
’s
cooling
airflow out of the operating work environment is recommended to avoid any ozone effects on workers or materials. All medium-
pressure arc lamps generate and emit ozone during start-up and operation. External exhaust installation is recommended because
the unit produces a small amount of ozone that might be a problem when exhausted to a confined or poorly ventilated space.
Main Components
Figure 3.
WIDECURE
Conveyor
Light-Blocking
Curtains
Belt
Adjustment
Screws
HMI/LCD Display
Belt
E-Stop
Front Access
Door
Irradiator
Access Door
E-Stop