System Adjustments
Engineering Screen
From the Main Operating Screen (Figure 11), the Main Engineering Screen can be reached by pressing the blue engineering
button centered at the top of the screen. From the Main Engineering Screen you can access various sub screens: conveyor belt
settings, UV lamp settings, and panel configuration.
Under the system units heading, the user can choose either English or metric units. The English units are feet per minute (FPM) for
the conveyor speed, and inches for the stage height. The metric units are meters per minute (MPM) and centimeters for the stage
height.
Figure 12. Engineering Main Menu
Conveyor Belt Settings
The Conveyor Belt Settings Sub Screen (Figure 13) shows the statistics of the conveyor belt drive and if there are any fault codes.
Fault codes can be referenced from the Allen Bradley Power Flex 525 Drive Manual. If a fault code exists, p
ress “Clear Fault” to
reset the drive. Additionally, the acceleration and deceleration times of the drive can be changed to accommodate the
synchronizing of upstream and downstream processes. The acceleration/deceleration range is 1-30 seconds.