Troubleshooting
WARNING!
Only qualified maintenance personnel should attempt the following procedures.
Table 1. Troubleshooting Chart
Problem
Possible Cause
Testing
Corrective Action
Conveyor Not
Operating
Main Line Circuit Breaker
tripped.
Toggle Power Switch off, then on.
Find cause of tripped breaker.
Improperly fastened electrical
Connections.
Check all connections.
Properly fasten electrical
connections.
Fuses for Motor Controller
blown.
Remove Fuses from Fuse Holders
(located in the left side of control box
of unit) and check with an Ohmmeter.
Replace Fuses if defective.
Belt is hung up.
Inspect the Belt for any signs of a
mechanical bind.
Resolve bind and continue
operation.
Tension too low on Belt (Power
Switch lights and Motor turns
but Belt does not move).
Verify the operation of the Drive Shaft
and Drive Rollers.
Use the tracking adjustment
screws to increase the tension
on the Belt. Both knobs need to
be turned the same amount to
maintain alignment.
Error displayed on HM! screen
Find error in engineering screen
Clear error. If error repeats,
investigate root cause of error.
Belt Tracks to
One Side
Belt Adjustment Screws are out
of position.
Visually inspect the Belt. The Belt will
track to one side.
Tighten the Belt Adjustment
Screw (the one located on the
side to which the Belt is tracking
towards) until Belt tracks
straight. Only minor adjustments
should be made at one time.