D Y MA X. COM
W I D ECU RE
®
C ONV EY O R U S ER G U I D E
|
19
Figure 19. Remove Black Panel on Left Side of Conveyor
5.
On the right side of the opening, towards the front of the conveyor, is a black-louvered fan cover. This cover can be removed
by placing a flat-blade screw driver between the cover and the electrical housing and lifting the cover away from the housing
(Figure 20).
Figure 20. Fan Cover
6.
Once the fan cover has been removed, the fan filter can be lifted away from the assembly and replaced with a new filter.
7.
When the new filter has been installed, replace the fan cover by lining it up to the opening and pressing it back into place.
8.
Reinstall the side panel and the blue corner trim pieces before restoring electrical supply to the
WIDECURE
system.
Bulb Replacement
CAUTION!
Never touch a UV lamp with your bare hands. Always wear clean protective gloves before servicing the irradiator
assembly. If accidental contact with the lamp occurs, gently wipe the lamp
’s
surface with isopropyl alcohol (IPA) and a soft, lint-free
cloth to remove any finger oils.