12
Dymax EC-Series Flood Lamps for UVCS Conveyors User Guide
■
If Reflector temperature is below 115° F, remove the Reflector Cover and install the second
Temperature Control Plate. If temperature is above 145° F, remove the Reflector Top and remove
the Reflector Plate.
Figure 11. 5000-EC
Securing Screws
Figure 12. Temperature Control Plate
and Temperature Indicating Strip,
Installed
Cleaning and Maintenance
Bulb Replacement Procedure
Every new EC-Series Flood Lamp is supplied with a new 400 Watt Bulb. When the Bulb requires replacement,
the following procedure must be followed.
1.
Turn the Power Switch off.
2.
Disconnect the Power Supply from the electrical power source.
3.
Allow the Bulb to cool.
CAUTION!
The Bulb operates at temperatures exceeding 500°C. Touching the Bulb before
sufficient cooling may cause severe burns.
Always wear safety eye wear while replacing Bulb.
4.
Hold the Lamp/Reflector Assembly Housing securely and loosen thumbscrew on the Lamp/Reflector
Assembly Housing Bracket. Lift the Lamp/Reflector Assembly Housing off the Mounting Stand and
place upside down on a clean work surface.
5.
Reach into the Reflector and grasp the flat area of Bulb at either end (Figure 13).