21
BlueWave® MX-Series Multichannel Controller User Guide
Operation
To operate the controller, first verify that all Connectors are correctly plugged into the rear panel of the unit (See
System Connections
, pg. 13 for more details). When all Connectors are properly plugged in, press the Power Button
on the front panel of the unit.
Upon startup of the unit, a splash screen will appear. After 6 seconds, the control screen should appear in the
display. It will be in administrator mode the first time the unit is started.
Admin Screen
The control screen is used to set up and run curing cycles. This screen allows users to switch back and forth
between Administrator, Production and PLC modes. It is also where the curing parameters are set.
Figure 18. Admin Screen
Touch Screen Interface
The touch screen uses two types of inputs via the touch screen:
Buttons (B)
which executes an action
Display/Buttons (DB)
which indicates a status or parameter but also functions as a button
The following are general descriptions of the inputs found on the system touch screens. The type of input is
denoted by a (B) or (DB) next to the name.
Information (B):
Advances to system information screen.
Information
Triggers
User Mode
Settings
Program Status
Emitter Data
Manual Mode
Timed Mode
Alarms Icon
Channel Parameters
Ch
–
Channel # & Mode
T(s) - irradiating time
P(%) - Emitter Power
D(s) - Emitter Delay
Tr - Emitter Trigger
Emitter Power