PLC (Programmable Logic Controller) Operation
When in PLC mode, an external PLC can control
the unit. The PLC provides input signals to the
BlueWave
MX-Series 1CH system to control the
on/off signals and intensity of the LED. The PLC
monitors the status of the system by reading
output signals provided by the unit.
The PLC is typically programmed to start other
machinery when the
BlueWave MX- Series 1CH
system becomes ready, or something starts the
unit when other machinery is ready. The input
and output signals are present on connector (J5)
located on the back of the unit.
NOTE: A ferrite will be required on the PLC
(0-10V) analog input cable to reduce noise.
Ferrite bead (PN 0443164251) installed on the
analog PLC cable (looped once) at the EUT end.