Model 485 Dispensing Systems User Guide 

 
 

 

Safety 

Using Safe Operating Pressures 

Pressurizing the components in the dispensing system beyond the maximum 
recommended pressure can result in the rupturing of components and serious personal 
injury. To minimize the risk of rupturing components and injury, do not exceed the 
maximum operating pressure of the components in your fluid dispensing system. 

Operating Specifications 

■ 

Recommended compressed air supply pressure to air filter/regulator = 

80 to 100 psi (5.5 to 6.9 bar) 

■ 

Recommended pressure setting at air filter/regulator = 75 psi (5.2 bar) 

■ 

Maximum pressure setting at air filter/regulator = 100 psi (6.9 bar) 

■ 

Power required = 110V power receptacle (customer supplied)  

Содержание 485

Страница 1: ...Model 485 Dispensing Systems Systems User Guide ...

Страница 2: ...ing Tips 6 System Configurations 7 A Systems Using a Cartridge Retainer 8 Packaged Components 8 Assembled System 9 B Systems Using a Bottle Drop In Tank 10 Packaged Components 10 Assembled System 11 Installing the Fluid Line to the Reservoir 12 C Systems Using a 10 Gallon Pressure Tank 13 Packaged Components 13 Assembled System 14 Installing the Fluid Line to the Reservoir 15 ...

Страница 3: ...mize the risk of rupturing components and injury do not exceed the maximum operating pressure of the components in your fluid dispensing system Operating Specifications Recommended compressed air supply pressure to air filter regulator 80 to 100 psi 5 5 to 6 9 bar Recommended pressure setting at air filter regulator 75 psi 5 2 bar Maximum pressure setting at air filter regulator 100 psi 6 9 bar Po...

Страница 4: ...timed dispense mode Dispensing Valve Accessories Dymax dispensing valves for handheld and bench top applications deliver precision solutions for low to high viscosity materials Various style tips and accessories are also available Reservoirs Dymax carries a variety of material reservoirs to accommodate most dispensing applications Range of volumes from 6 oz cartridges to 10 gallon pressure tanks E...

Страница 5: ...ons Figure 2 Controller Connections Rear Panel Figure 3 High Precision Regulator Connections Figure 4 Filter Regulator Fluid in From reservoir Air in from controller Air in from filter regulator Power supply input Foot switch input Air out to valve Air in from filter regulator Air out to reservoir Supply air in Air to controller reservoir ...

Страница 6: ...spensing valve Either tip kit can be used depending on the exact viscosity and application P3424 Dispensing Tip Kit for Low Viscosity Materials 500 cP Part Color Description P3171 Purple 21 GA Needle Tip P3172 Orange 23 GA Needle Tip P3233 Pink 20 GA Tapered Tip P3247 Red 25 GA Tapered Tip P3423 Dispensing Tip Kit for Medium to High Viscosity Materials 500 cP Part Color Description P3169 Amber 15 ...

Страница 7: ...Model 485 Dispensing Systems User Guide 7 System Configurations A Systems Using a Cartridge Retainer p 8 9 B Systems Using a Bottle Drop In Tank p 10 12 C Systems Using a 10 Gallon Pressure Tank p 13 15 ...

Страница 8: ... System User Guide T11146 DVC 345 Controller Cartridge Reservoirs 6 oz T15257 12 oz T14085 20 oz T15223 T16629 High Precision Regulator T16307 Filter Regulator T16787 3 8 OD Fluid Line Kit T16786 Controller Air Line Kit T16789 Reservoir Air Line Kit T17617 Model 485 Needle Valve T16857 Mounting Assembly T16793 Fluid Line Kit 1 4 OD ...

Страница 9: ...17617 Model 485 Needle Valve T15279 Lab Stand 24 61 cm T16857 Mounting Assembly T11146 DVC 345 Controller Cartridge Reservoir 6 oz T15257 12 oz T14085 20 oz T15223 T16629 High Precision Regulator T16307 Filter Regulator T16786 Controller Air Line Kit T16787 Fluid Line Kit 3 8 OD T16789 Reservoir Air Line Kit T16793 Fluid Line Kit 1 4 OD P3423 Dispensing Tip Kit P3424 Dispensing Tip Kit ...

Страница 10: ...04 1 Gallon Bottle Drop In Tank T17736 System User Guide T11146 DVC 345 Controller T16307 Filter Regulator T15279 Lab Stand 24 61 cm T17617 Model 485 Needle Valve T16857 Mounting Assembly T16787 3 8 OD Fluid Line Kit T16786 Controller Air Line Kit T16789 Reservoir Air Line Kit T16793 Fluid Line Kit 1 4 OD ...

Страница 11: ... quick disconnect fitting T17617 Model 485 Needle Valve T15279 Lab Stand 24 61 cm T11146 DVC 345 Controller T17004 1 Gallon Bottle Drop In Tank T16307 Filter Regulator T16786 Controller Air Line Kit T16787 Fluid Line Kit 3 8 OD T16789 Reservoir Air Line Kit T16857 Mounting Assembly T16793 Fluid Line Kit 1 4 OD P3423 Dispensing Tip Kit P3424 Dispensing Tip Kit ...

Страница 12: ...nsing Systems User Guide 12 Installing the Fluid Line to the Reservoir Tube length from top of fitting 14 5 End of tubing must be cut at an angle 1 Liter Bottle 1 Gallon Bottle Air Line Fluid Line Air Line Fluid Line ...

Страница 13: ... T16864 10 Gallon Pressure Tank T11146 DVC 345 Controller T16307 Filter Regulator T17736 System User Guide T15279 Lab Stand 24 61 cm T17617 Model 485 Needle Valve T16857 Mounting Assembly T16787 3 8 OD Fluid Line Kit T16786 Controller Air Line Kit T16789 Reservoir Air Line Kit T16793 Fluid Line Kit 1 4 OD ...

Страница 14: ... to quick disconnect fitting T11146 DVC 345 Controller T16864 10 Gallon Pressure Tank T16307 Filter Regulator T16786 Controller Air Line Kit T16787 Fluid Line Kit 3 8 OD T16789 Reservoir Air Line Kit T16793 Fluid Line Kit 1 4 OD T16857 Mounting Assembly T17617 Model 485 Needle Valve T15279 Lab Stand 24 61 cm P3424 Dispensing Tip Kit P3423 Dispensing Tip Kit ...

Страница 15: ...Model 485 Dispensing Systems User Guide 15 Installing the Fluid Line to the Reservoir Tube to be flush with the bottom of the lid tube 15 Liter Pail ...

Страница 16: ... is willing to assist users in their performance testing and evaluation Data sheets are available for valve controllers or pressure pots upon request MAN060 T17736 11 4 2013 Dymax Corporation 860 482 1010 info dymax com www dymax com Dymax Europe GmbH 49 0 611 962 7900 info_de dymax com www dymax de Dymax Asia Pacific Pte Ltd 65 6752 2887 info_ap dymax com www dymax ap com Dymax Asia H K Limited 8...