Dwyer Instruments VP3 Скачать руководство пользователя страница 1

The 

Model VP3 Wireless 100 mm Vane Thermo-Anemometer Probe 

measures air velocity, air flow, humidity, and temperature with the UHH4 

or newer universal handheld device, or your own mobile device. By having 

a larger diameter, the rotating vane is able to measure velocities down to 

50 fpm or 0.25 m/s. An arrow is molded into the vane housing to depict the 

flow direction. 

 

Wireless probes can take measurements up to 50 feet away from the base 

unit. A bicolor LED flashes on the handle of the probe to indicate 

communication status with the base unit. The battery is rechargeable via 

the mini-USB connector on the bottom of the probe. 

 

                        This device complies with Industry Canada license-exempt RSS  

                        standard(s). Operation is subject to the following two 

conditions: (1) This device may not cause harmful interference. and (2) this 

device must accept any interference received, including interference that 

may cause undesired operation. 

 

Cet appareil est conforme à des règlements d’Industrie Canada exempts de 

licence standard RSS (s). Son fonctionnement est soumis aux deux 

conditions suivantes: (1) Ce dispositif ne doit pas causer d’interférences 

nuisibles, et (2) cet appareil doit accepter toute interférence reçue, y 

compris les interférences pouvant entraîner un fonctionnement 

indésirable. 

 

This Class B digital apparatus complies with Canadian ICES-003. 

Cet appareil numériqué de la classe B est conformé à la norme NMB-003 

du Canada. 

 

CHARGING BATTERY

 

                        It is required prior to the initial usage to charge the battery for  

                        12 hours.

 

When the charge of the battery is almost used up, the LED on the handle of 

the wireless probe will turn solid red. There is approximately 5 minutes of 

battery life left at this point. If the probe is not already paired to the UHH, it 

will not pair while in low battery condition. 

 

Step 1: Open the USB cover on the bottom of the probe handle. 

Step 2: Plug the mini-USB connector end of the cable into the probe handle. 

Step 3: Plug the USB connector end of the cable into the port on the charger or PC. 

Step 4: Plug the charger into either an electrical outlet or car charging port (LED on 

the charger and the handle should both light up). 

Step 5: The LED on the handle will turn off when fully charged. 

Step 6: Remove charger from electrical outlet. 

Step 7: Remove USB connectors from the handle and the charger. 

Step 8: Replace the USB cover on the bottom of the probe handle.

 

Model VP3 Wireless 100 mm Vane Thermo-Anemometer Probe

 

SPECIFICATIONS 

Service: 

Clean air. 

Temperature Limits: 

Process: -4 to 140

°

F (-20 to 60

°

C); Ambient: 5 to 125

°

F (-15 to 

51

°

C). 

Range: 

Air velocity: 50 to 5000 fpm (0.25 to 25 m/s); Temperature: -22 to 140

°

(-30 to 60

°

C); Relative humidity: 0 to 100% RH; Air volume: 999,999 in selected 

units. 

Accuracy: 

Air velocity: 0.25 to 10 m/s: 

±

1.5% of reading 

±

20 fpm (

±

0.1 m/s); 10 to 20 

m/s: 1.5% of reading 

±

40 fpm (

±

0.2 m/s); 20 to 25 m/s: 

±

1.5% of reading 

±

60 fpm (

±

0.3 

m/s); Temperature: 

±

0.54

°

F @ 77

°

F (

±

0.3

°

C @ 25

°

C); Relative humidity: 

±

2% @ 77

°

(25

°

C) (10 to 90% RH); 

±

4% (0 to 10% and 90 to 100%). 

Response Time: 

Air velocity: 1 s; Temperature: 1.5 s; Relative humidity: 1.5 s; Air 

volume: 1 s. 

Probe Length: 

8˝ (203 mm) insertion.

 

Power Requirements: 

3.7 V YT562447 lithium ion battery, installed functional, user 

replaceable. 

Battery Charging Limits: 

32 to 113

°

F (0 to 45

°

C). 

Maximum Wireless Distance: 

50

´

 (15 m). 

Vane Material: 

Anodized aluminum. 

Handle Enclosure: 

Thermoplastic elastomer over polycarbonate. 

Supplied With: 

Wrist strap. 

Weight: 

13.6 oz (402.20 g). 

Supported Devices: 

UHH4 or newer universal handheld, and  smart devices that 

support  Bluetooth® LE (Bluetooth® Low Energy). 

Supported Operating Systems:  

Android® firmware version 3.X or later, iOS® firmware 

version 5.X or later. 

Bulletin TE-VP3 

                        Lithium ion polymer batteries are very volatile and can cause  

                        a fire if punctured or severely damaged. Only use a Dwyer 

Instruments, Inc. approved charging device in a well ventilated area away 

from any flammable materials or gases. Do not incinerate the battery. Only 

charge between 32 to 113°F (0 to 45°C). 

 

                        If desired, can be operated with USB cables less than 3 m in    

                        length when connected to the charger or PC. 

Отзывы: