Dwyer Instruments IS626 Series Скачать руководство пользователя страница 1

The Dwyer Series IS626 Pressure Transducer 

convert pressure into a

standard 4-20 mA output signal. The Series IS626 can be used to accu-

rately measure compatible gases and liquids. Series IS626 full scale ac-

curacy  is  0.25%  (see  specifications).  Designed  for  industrial

environments with a NEMA 4X (IP66) housing, this transmitter resists

most effects of shock and vibration.

Intrinsic Safety Approval Classification

The IS626 is UL listed for use in Hazardous (Classified) Locations.  The

protection method is by Intrinsic Safety, “ia”.  It was investigated by UL

under UL Standard 913 8th Edition, CAN/CSA C22.2 No. 60079-0:15 and

CAN/CSA C22.2 No. 60079-11:14.

Hazardous (Classified) Location Intrinsically Safe For:

Class I Div. 1 Groups A,B,C,D

Class II Div. 1 Groups E,F,G

Class III Div. 1 

Class I Zone 0 AEx ia IIC T4 Ga

Zone 20 AEx ia IIIC T135°C Da

Ex ia IIC T4 Ga

Ex ia IIIC T135°C Da

Ta = -20°C to 80°C 

Install in accordance with Control Drawing 001833-42. 

See Control Drawing 001833-42 for Entity Parameters.

ATEX: EU TyPE CErTIFICATE NO. DEMkO 18 ATEX 2080

ATEX STANDArDS: EN 60079-0:2012/A11:2013

EN 60079-11:2012 

ATEX CLASSIFICATION:       0518      II 1 G Ex ia IIC T4 Ga (-20°C ≤

Tamb ≤ 80°C)

0518      II 1 D Ex ia IIIC T135°C Da (-20°C ≤ Tamb ≤ 80°C)

IECEx CErTIFICATE OF CONFOrMITy: IECEx UL 18.0086

IECEx STANDArDS: IEC 60079-0: 2011 6TH ED. 

IEC 60079-11:2011 6TH ED.

IECEx CLASSIFICATION: Ex ia IIC T4 Ga (-20°C ≤ Tamb ≤ 80°C)

Ex ia IIIC T135°C Da (-20°C ≤ Tamb ≤ 80°C)

INSTALL IN ACCOrDANCE wITH CONTrOL DrAwING 001833-45

SEE CONTrOL DrAwING 001833-45 FOr ENTITy PArAMETErS.

Series IS626 Pressure Transducer

Specifications - Installation and Operating Instructions

Bulletin E-IS-626

SPECIFICATIONS

Service: 

Compatible gases and liquids.

Wetted Materials: 

Type 316, 316L SS.

Accuracy: 

0.25% full scale (includes linearity, hysteresis, and repeata-

bility).

Temperature Limit: 

-4 to 176°F (-20 to 80°C).

Compensated Temperature Range: 

-4 to 176°F (-20 to 80°C).

Thermal Effect: 

±0.02% FS/°F (includes zero and span).

Pressure Limits:

2X full scale.

Power Requirements: 

10 to 28 VDC.

Output Signal: 

4 to 20 mA. 

Response Time: 

50 msec.

Loop Resistance: 

0 - 900 ohms maximum. 

Current Consumption: 

38 mA (maximum).

Electrical Connections: 

3 ft. cable or 4-pin M-12 Connector.

Process Connection: 

1/4˝ male/female NPT and BSPT.

Enclosure Rating: 

NEMA 4X (IP66) (Self Declared by Dwyer Instru-

ments, Inc.).

Mounting Orientation: 

Mount in any position.

Weight: 

8.9 oz (252 g).

Agency Approvals: 

CE, See Intrinsic Safety Approval Classification.

MALE NPT/BSPT CONNECTOR WITH CABLE GLAND

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/4 NPT or
  1/4 BSPT

1-1/16 [26.99] HEX

5-3/16 [131.75]

6-1/4 [158.75] MAX

ø1 [25.40]

 

 

 

 

 

1/4 NPT OR

1/4 BSPT

1-1/16 [26.99] HEX

MALE NPT/BSPT CONNECTOR WITH MALE M-12 CONNECTOR

5-1/16 [128.58]

5-21/32 [143.67]

ø1 [25.40]

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ø1 [25.40]

1-1/16 [26.99] HEX

5-1/16 [128.58]

5-21/32 [143.67]

FEMALE NPT/BSPT CONNECTOR WITH MALE M-12 CONNECTOR

1/4 NPT OR

1/4 BSPT

FEMALE

 

 

 

 

 

 

   

 

 

CD

       = CRITICAL DIMENSION
STANDARD TOLERANCES UNLESS NOTED:
ALL DECIMAL DIMENSIONS ± /005
ALL ANGLES ± 1’

 

FEMALE NPT/BSPT CONNECTOR WITH CABLE GLAND

1-1/16 [26.00] HEX

5-3/16 [131.76]

5-1/4 [158.75]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/4 NPT OR

1/4 BSPT

FEMALE

 

 

 

   

 

ø1 [25.40]

         

 

 

 

 

 

 

   

 

   

 

DWYER INSTRUMENTS, INC. 

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A. 

Fax: 219/872-9057

e-mail: [email protected]