Dwyer Instruments 473B Скачать руководство пользователя страница 1

Model 473B 100 mm Vane Thermo-Anemometer Test Instrument

Specifications - Installation and Operating Instructions

Bulletin TE-473B

The 

MODEL 473B

 100 mm Vane Thermo-Anemometer Test Instrument is a versatile 

unit that quickly and easily measures air velocity or volumetric air flow, as well as air 

temperature and humidity in imperial or metric units. A stainless steel 100 mm vane 

probe is included, which has a comfortable hand grip. The extruded aluminum housing 

fully protects electronics, yet is lightweight and comfortable to hold.

16-3/4

[425.62]

6-1/32

[153.16]

4-13/64

[106.65]

2-13/16

[71.44]

6-5/32

[156.52]

SPECIFICATIONS

Service:

 Dry, clean air.

Temperature Limits:

 Process: -20 to 

212°F (-29 to 100°C); Ambient: 5 to 

125°F (-15 to 51°C)

Display:

 4.5 digit backlit display.

Range:

 Air velocity: 40 to 5000 fpm (0.2 

to 25 m/s); Volumetric air flow: 19,999 in 

selected flow units; Temperature: -20 to 

212°F (-29 to 100°C); Relative humidity: 

0 to 100% RH.

Accuracy:

 Air velocity: ±1.5% of reading 

±20 fpm (±0.1 m/s) [0.25 to 10 m/s]; 

±1.5% of reading ±40 fpm (±0.2 m/s) [10 

to 20 m/s]; ±1.5% of reading ±60 fpm 

(±0.3 m/s) [20 to 25 m/s]; Temperature: 

±0.54°F @ 77°F (±0.3°C @ 25°C); 

Relative Humidity: ±2% @ 77°F (25°C) 

[10 to 90% RH]; ±4% [0 to 10, 90 to 

100% RH].

Response Time:

 Air velocity: 1 s; 

Volumetric air flow: 1 s; Temperature: 1.5 

s; Relative humidity: 1.5 s.

Probe Length:

 8˝ (203 mm) insertion.

Cable Length:

 28˝ (71 cm) retracted; 6´ 

(18.3 m) extended.

Vane Material:

 Anodized aluminum.

Power Requirements:

 9 V alkaline 

battery, installed non-functional, user 

replaceable.

Weight:

 18.4 oz (521 g).

Agency Approvals:

 CE.

BATTERY INSTALLATION

The unit is shipped with a separate 9 V alkaline battery which must be installed before 

operation. Remove the two screws holding the bottom endcap in place and remove it. 

Connect the battery to the enclosed battery clip, observing correct polarity. Be careful 

not to trap the wires between the case and the foam pad which retains the battery. This 

could make it difficult to install the battery or remove it later for replacement. Be sure 

the rubber gasket is properly seated in the gasket channel and replace the endcap. 

Note that the endcap will only fit one way because the holes are slightly off-center. 

Place the “Z” shaped wrist strap clip in one of the screw recesses and replace the 

screws. Do not overtighten. Attach the wrist strap to the clip.

When battery replacement becomes necessary, use only 9 V alkaline type batteries 

such as Duracell

®

  MN1604,  Eveready

®

  522  or  equivalent.  Zinc-carbon  types,  often 

labeled  Heavy-Duty,  are  not  recommended  because  of  their  shorter  life  and  an 

increased potential for leakage. Alkaline batteries are a better value because they last 

typically up to three times longer in this device.

LOW BATTERY INDICATOR

A  weak  battery  may  cause  improper  operation  or  inaccurate  measurements. A  low 

battery indicator (       ) is provided on the display to show when the battery needs to 

be replaced. Although the unit may appear to function and read properly, the accuracy 

of the readings cannot be guaranteed when the (       ) indicator is empty of power 

segments. Replace the battery with a fresh one. Do not leave an exhausted battery in 

the unit due to potential battery leakage.

Duracell

®

 is a registered trademark of The Gillette Company

Eveready

®

 is a registered trademark of Eveready Battery Company, Inc.

OPERATING INSTRUCTIONS

ON/OFF/LIGHT

A single press turns unit on, and a second press turns unit off. While unit is on, hold for 

2 seconds to turn on the backlight. If the light is active, press once to turn the light off 

and another to turn the unit off.

HOLD

A single press freezes the current reading and a second press resumes live process 

reading.

MENU

A single press will display the menu. Hit MENU while in the main menu to go back to 

the home screen or while in the sub-menus to back up one level.

ENTER

When in the home screen, press to cycle through temperature, dew point, wet bulb, air 

velocity, and flow. While in the menu, press to enter sub-menus or values. Press and 

hold for 4 seconds to clear MAX, MIN, or MEM in their respective menus.

MEMORY/UP

A single press will retrieve stored data points in the memory. Each successive press 

will scroll to the next saved memory location ST01, ST02, etc. While in the menu, it 

becomes the UP button.

STORE/DOWN

A single press will store the current reading on the screen. ST01, ST02, etc. shows in 

the display to indicate the memory location where the reading was saved. While in the 

menu, it becomes the DOWN button.

DWYER INSTRUMENTS, INC.

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.

Phone: 219/879-8000
Fax: 219/872-9057

www.dwyer-inst.com
e-mail: [email protected]

®