OPM BWT PERMAQ® Pico Rev. 2.0 EN
Technical data | 10
EN
49
10 Technical data
10.1 Technical data for the BWT PERMAQ® Pico 10-90 on/off
10
20
30
40
50
60
70
80
90
Permeate:
Offline output,
free run-off
1)
l/h
> 180 > 250 > 440 > 580 > 1150 > 1620 > 1950 > 2160 > 2520
Offline output,
free run-off
2)
l/h
> 200 > 300 > 500 > 650 > 1250 > 1800 > 2100 > 2400 > 2800
Online output,
3.0
bar counter pressure
1)
l/h
> 140 > 180 > 280 > 450 > 900 > 1300 > 1500 > 1750 > 2100
Online output,
3.0
bar counter pressure
2)
l/h
> 160 > 210 > 360 > 510 > 1000 > 1400 > 1600 > 2000 > 2500
Salt retention rate
%
97
98.5
Permeate yield (WCF)
%
80
80
Feed water
Pressure range
bar
2.5 – 6.0
2.5 – 6.0
Temperature range
°C
5 – 30
5 – 30
Hardness/with antiscalant
dosing
°dH
°fH
0.0 / 25
0.0 / 45
0.0 / 25
0.0 / 45
Iron (Fe) and manganese
(Mn)
mg/l
< 0.1
< 0.1
Salt content, total dissolved
solids (TDS)
mg/l
< 1,000
< 1,000
Silt density index (SDI)
%/min
< 3
< 3
Oxidants
mg/l
< 0.05
< 0.05
Silicate (SiO
2
)
mg/l
< 20
< 20
Hydraulic connections:
Feed water
inch
3/4"
1"
Permeate
inch
3/4"
1"
Concentrate
mm
13
mm / FT version 8
mm
13 mm / FT version
10
mm
General
Degree of protection
IP
63
Ambient temperature
°C
5 – 35
Electrical connection / fuse
protection
V/Hz/
A
400 / 50 / 10
Electric power consumption kW
0.85
0.85
0.85
1.6
2.3
2.3
3.1
3.1
3.1
Type of valve
VDC
24
Connector standard
CEE
16; 3PNE
1)
Feed water: TDS ≤ 1,000
mg/l; 15
°C; 2.5
bar
2)
Feed water: TDS ≤ 1,000
mg/l; 15
°C; 4.0
bar
Table
13: