Using the Web Interface
45
7.4.6
Camera Functions
The
Camera Functions
screen is used for the following functions:
Display the camera temperature and heater duty cycle
Automatically calibrate the camera at set intervals
Enable/Disable constant recording
Heater Control
The
Camera Functions
screen opens on the
Heater Control
screen. The screen displays the camera
temperature and heater duty cycle. By default, the camera heater is enabled.
Caution:
The camera must be powered by 802.3at PoE+, or by a 12-24VDC or 24VAC power supply with at
least 20W output. An 802.3af PoE switch/injector does NOT have sufficient power to operate the
camera.
Figure
51
: Heater Control Screen
Auto Calibration Interval
The
Auto Calibration Interval
screen enables the camera to automatically calibrate itself and perform non-
uniformity correction (NUC) at frequent intervals. In addition, the camera will automatically perform NUC in
case a temperature change is detected.
Figure 52: Auto Calibration Interval Screen
To set the Auto Calibration Interval
1.
Choose the interval by using the slider. The NUC interval range is 5-60 minutes.
2.
Click
Set
.
3.
A popup window confirms the setting. The interval is set.