Dux Proflo 25S124P Скачать руководство пользователя страница 1

25L and 50L Electric Storage Water Heater

Owner’s Manual

Models:  

  25S124P, 25S136, N25S124P, 
N25S136, 50S124P, 50S136, 
N50S124P, N50S136

028299    Rev. C

Specifications and materials may change without notice.
Effective for the above model numbers of electric storage water heaters manufactured and 
sold after 1st March 2021.

For advice, repairs and service, call:
1300 365 115 (Australia)

 

0800 729 389 (New Zealand)

Carefully remove all packaging and 
transit protection from the heater before 
installation. Dispose of the packaging 
responsibly using re-cycling facilities 
where they exist.

Installation Details
Owner’s Information 
Warranty

Содержание Proflo 25S124P

Страница 1: ...or the above model numbers of electric storage water heaters manufactured and sold after 1st March 2021 For advice repairs and service call 1300 365 115 Australia 0800 729 389 New Zealand Carefully remove all packaging and transit protection from the heater before installation Dispose of the packaging responsibly using re cycling facilities where they exist Installation Details Owner s Information...

Страница 2: ...eks or more a quantity of hydrogen which is highly flammable may accumulate inside the water heater tank To dissipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not a dishwasher clothes washer or other appliance During this procedure there must be no smoking open flame or any other electrical appliance operating nearby If hydrogen ...

Страница 3: ...th the Wiring Rules If the power supply cord is damaged it must be replaced by the manufacturer a service agent or a similarly qualified person in order to avoid a hazard Any electrical covers should be removed only by a licensed tradesperson and only after the electrical supply to the water heater has been isolated When the supply wiring has been connected ensure the wires are kept lower than the...

Страница 4: ...certificate showing that the work complies with all the relevant Standards Only a licensed person will have insurance protecting their workmanship LOCATION The water heater should be located as close as possible to the most frequently used hot water outlet Ensure the compliance plate and associated warnings are clearly visible The water heater must be accessible without the use of a ladder or scaf...

Страница 5: ...portant Safety Information i Installation Requirements iii Plumbing Connections 2 Specifications 4 Filling and Draining 5 Electrical Connection 6 System Maintenance 7 Considering a Service Call 8 Warranty 9 Dux Manufacturing Limited 2021 All rights reserved Contents ...

Страница 6: ...f the water heater to supplementary energy sources such as solar panels or slow combustion stoves Refer to AS NZS 3500 4 for guidance on these types of installations Hot Water Connection The hot water pipe is to be connected to a RP DN20 socket with red surrounds at the top of the water heater The unused socket dual handed models only with red surrounds is to be plugged with one of the brass plugs...

Страница 7: ...heater is intended to be permanently connected to the water supply main and not connected by a hose set An approved isolating valve non return valve line strainer optional but recommended and union must be fitted between the water supply main and a RP DN20 socket with blue surrounds at the bottom of the water heater See the diagram on page 5 for details All fittings must be approved by the relevan...

Страница 8: ...Total Height A 455 670 Total Width B 405 405 Outlet Height C 275 490 Inlet Height D 145 145 Electrical Entry E 70 70 Dual Handed 25L 50L models Single Handed 50L model Single Handed 25L model Nominal Dimensions 25L 50L Total Height A 455 670 Total Width B 405 420 Outlet Height C 275 490 Inlet Height D 145 145 Electrical Entry E 70 70 Relief Valve Pressure kPa 1000 Temperature C 99 Power Rating kW ...

Страница 9: ... the lever gently and check it closes correctly Draining the Water Heater 1 Turn off the electricity supply to the water heater 2 Turn off the cold water supply to the water heater at the isolating valve 3 Gently operate the easing lever on the Pressure Temperature Relief PTR Valve to release the pressure in the water heater 4 Disconnect the cold water inlet union and attach a drain hose to the wa...

Страница 10: ... carried out by a licensed tradesperson Before removing the electrical cover ensure the electrical power supply is safely isolated Connections are made at the terminal block under the water heater electrical cover and a means for disconnection must be incorporated in the fixed wiring in accordance with the Wiring Rules The electrical cover may be removed by undoing the two screws at the bottom of ...

Страница 11: ...lve Confirm water discharges to waste through the drain pipe 3 Lower the easing lever gently and check it closes correctly 4 Repeat the above process for the expansion control valve if installed Other than this personally inspecting or servicing any part of the water heater is not recommended Five Year Service This service should only be carried out by a licensed tradesperson In locations where th...

Страница 12: ...ipping hot water tap A small leak can waste a large quantity of hot water Replace faulty tap washers and arrange for your plumber to rectify any leaking pipe work Is the Pressure Temperature Relief Valve discharging too much water See below Continuous Trickle of Water from Pres sure Temperature Relief PTR Valve This is most likely due to a build up of foreign matter In this case try gently raising...

Страница 13: ...ng the first year of warranty Dux will provide a replacement water heater free of charge including installation and labour costs Installation and other labour costs are the responsibility of the owner if the water heater is outside parts and labour warranty Warranty Conditions The warranty only applies to the water heater itself and the components supplied with the water heater by Dux The warranty...

Страница 14: ...ss to any property arising directly or indirectly out of or connected to the installation of the water heater This includes but is not limited to furnishings carpets foundations housing effects and buildings 2 for any direct or indirect economic or financial loss of any nature 3 arising out of or connected to a water heater that has been resold or moved from its original installation location 4 ar...

Страница 15: ...and contact number Provide proof of date of installation for warranty to commence from that date rather than from the date of manufacture See Commencement of Warranty on page 10 Please note if the defect or fault is not covered by the warranty or guarantee you will be responsible for the costs incurred by the service agent or technician Contact Details Dux Manufacturing Limited Lackey Road Moss Va...

Страница 16: ... s Licence No Installer s Signature www dux com au warranty Please Register Your Water Heater Please take a moment to fill out your details for warranty registration at This will ensure all your current details are registered with us for prompt warranty service if required To view our privacy policy please visit http www dux com au p privacy or use your smartphone to scan this code 028299 Rev C ...