Specifications and materials may change without notice.
Effective for electric boosted solar water heaters manufactured and sold after 1 January 2012.

Installation by a licensed tradesperson and in 
accordance with:

•  AS/NZS 3500.4 “National Plumbing & 

Drainage Code Hot Water Supply Systems 
– Acceptable Solutions”

•  Adherence to local authority and OH&S 

regulations

•  Victorian PIC Requirements

Carefully remove all packaging and 
transit protection from the heater before 
installation. Dispose of the packaging 
responsibly using re-cycling facilities 
where they exist.

H3163    025247    Rev. C

For advice, repairs and service, call:
1300 365 115 (Australia)       
0800 729 389 (New Zealand)

Models: 

2F136S 
2F136SD 
3F136S 
3F136SD 
4F136S 
4F136SD

2S136ED 
3S136ED 
4S136ED

Installer’s Guide

Important InFormatIon

 

For an easier installation, please read this document before you begin.

On completion, sign and leave with owner.

Electric Boosted Solar  
Water Heater

Содержание 2F136S

Страница 1: ...rian PIC Requirements Carefully remove all packaging and transit protection from the heater before installation Dispose of the packaging responsibly using re cycling facilities where they exist H3163...

Страница 2: ...lination 8 Collectors Important Points 9 Collectors Attaching to Roof 10 Collectors Attaching Fittings 12 4 Way Union Assembly 15 Anti Frost Valve 16 Flashing 17 Temperature Sensor 18 Only if installi...

Страница 3: ...ugh length of pipe to allow easy connections 250 L 315 L 400 L Tank Height 1444 1754 1704 Overall diameter 617 617 705 A Hot water outlet 1211 1521 1445 B Tempered water outlet mid way between A and D...

Страница 4: ...es 2S136ED 250 Yes 3F136S 315 No 3F136SD 315 Yes 3S136ED 315 Yes 4F136S 400 No 4F136SD 400 Yes 4S136ED 400 Yes Read This Document First Step 1 This Installer s Guide and the Owner s Manual also includ...

Страница 5: ...rk Method Statements WMS or Job Site Analysis JSA Prior to working at heights it is the responsibility of the installer to ensure that all practices are compliant with any relevant OH S legislation No...

Страница 6: ...ely position new storage tank on a level surface in accordance with all plumbing and building regulations Note We recommend a plinth be installed under the water heater where the water heater is subje...

Страница 7: ...l regulations and the plumbing code fit any and all valves that are necessary e g tempering valves pressure limiting valves line strainer duo valves cold water expansion valves etc We recommend the us...

Страница 8: ...suitable for solar working temperatures We recommend Armaflex DuoSolar Solar insulation minimum 13mm thick refer to local regulations Note Warranty will be void if this minimum insulation requirement...

Страница 9: ...inside the roof cavity if possible Take care when running flow and return lines through the roof cladding and the eaves Note Where roof and the eaves are made from asbestos specialised handling and ad...

Страница 10: ...tation please account for the Magnetic Declination of your geographic location Collector Inclination Guide C A C A Preferred range B Industry accepted range C If orientations A or B are not practical...

Страница 11: ...er inspection Critical Do not leave collectors pressurised for longer than 24 hours To prevent damage collectors should be left pressurised only when connected to the storage tank with appropriate pre...

Страница 12: ...er or greater if roof allows Note Ensure that the rail is parallel with the gutter Step 10 For Metal Roofs Only Fix roofing screws through the mounting straps on both sides using rubber grommets to pr...

Страница 13: ...the roof truss Note A minimum of 3 roofing screws of 40mm length must be used to fix the collector strap to the truss Ensure collector strap is located on truss vertically Repeat this process for the...

Страница 14: ...n hold fitting A see illustration in margin while tightening nut B to prevent twisting the header pipe Critical Do not use multi grips or similar tool as you will damage the brass fittings Ensure you...

Страница 15: ...14 Repeat the process for the second collector Note Ensure this is done with full consideration to OH S regulations Care should be taken Step 15 Now position the top mounting rail and repeat the abov...

Страница 16: ...ts to the bottom of the collectors the solar return hot pipe connects to the top of the collectors diagonally opposite to the solar cold pipe connection We suggest when you install pipes through roof...

Страница 17: ...ector inlet pipe The air bleed valve must stand vertically straight towards the sky Note If installed in top left bottom right of collector then T should be reversed When fitting the 4 Way Union assem...

Страница 18: ...WO anti frost valves must be installed if you live in alpine areas or areas subject to extreme frost such as the ACT and Snowy Mountain regions The anti frost valve comes in kit form and must be order...

Страница 19: ...proved method of flashing on the flow and return lines e g Dektite or lead collars Where flow and return lines penetrate the roof surface the penetration must occur on the high side of the roof profil...

Страница 20: ...clip Cable securing clip Collector temperature sensor Sensor secured by clip Warning Extreme care must be taken to not damage the sensor by pulling on collector temperature sensor Warning Install the...

Страница 21: ...he collector temperature sensor cable is exposed to atmosphere you must insulate the cable from UV radiation damage Warning Sensor connector pins align one way only When attaching sensors carefully al...

Страница 22: ...s as it may melt and cause signal interference Connect collector sensor cable to terminal block labelled Collector Sensor as shown in diagram There is no polarity for which collector sensor cable goes...

Страница 23: ...er heater We recommend fitting the non return valve at the solar return pipe connection Ensure the non return valve is installed so that the flow direction arrow faces the storage tank All pipe work m...

Страница 24: ...cted to the the PTR drain line Warning Extreme care should be taken as this drain down line may discharge very hot water once the system is operating It must be safely plumbed to waste as per AS NZS 3...

Страница 25: ...ly is needed Separate continuous electrical power must be supplied to the Hotlogic controller This ensures the protection features are enabled Warning Power cables should be routed away from any hot w...

Страница 26: ...ecommendations Commissioning the System Step 26 When the power is turned on the Hotlogic will go through initialisation Sensors red and Power green status lights will alternate for 4 seconds After the...

Страница 27: ...water pipes connected 5 Collectors aligned and attached to roof 6 11 Fittings attached to collectors 12 16 4 Way Union Assembly fitted 17 Anti Frost Valve fitted 18 Roof penetration sealed with a flex...

Страница 28: ...mentation supplied with the water heater Upon completion of installation this document must be given to the home owner in its entirety When required by the manufacturer the home owner will provide thi...

Страница 29: ...1 7 5 2 3 4 8 6 System Components 1 Solar electric tank assembly 2 Solar collector 3 Solar collector flow connection 4 Solar collector flow pipe 5 Automatic air vent valve 6 Solar collector return pip...

Страница 30: ...D 10 DETAIL E 13 12 11 16 15 14 System Components 1 Automatic air vent valve 2 Bush 3 15mm female tee 4 Union 15mm M 15mm C 5 Sensor dry well 6 Hex nipple 7 Union 1 C M 8 Union conetite DETAIL A 1 2...

Страница 31: ...A B C DETAIL A 1 2 3 4 5 6 3 7 DETAIL B 8 DETAIL C SCALE 1 10 9 DETAIL D 10 DETAIL E 13 12 11 16 15 14 C DETAIL A DETAIL C SCALE 1 10 9 DETAIL E 13 12 11 16 15 14 System Components 9 End stop 1 conet...

Страница 32: ...Electric Boosted Solar H3163 025247 Rev C Installer s Guide...