background image

DO NOT DISCARD THIS MANUAL: Retain for future use

30003851  9/10  Rev. 6

If this heater is not properly installed, operated, and maintained, a house fire may result. 
For safety, follow all installation, operation and maintenance directions. Contact local 
building officials about restrictions and installation inspection requirements in your 
area.

SAFETY NOTICE

R

Homeowner’s 
Installation and 
Operating Manual

2278

Dutchwest

noncat

cover

5/04

Non-Catalytic 
Convection 
Heater  
Model 2479CE

For use in Europe

Содержание 2477CE

Страница 1: ...may result For safety follow all installation operation and maintenance directions Contact local building officials about restrictions and installation inspection requirements in your area SAFETY NOTI...

Страница 2: ...tion 4 Assembly 11 Operation 13 Maintenance 18 Draft Management 21 Replacement Parts 24 Warranty 27 Accessories Clearance reducing Right Side Heat Shields Clearance reducing Heat Shields for single wa...

Страница 3: ...e mass gas flow 7 7 g s CO Emissions 13 O2 700 ppm Loading Side and front Chimney connector 152 mm 6 diameter Chimney flue size 152 mm 6 diameter Flue exit position Top or rear Air control One Ash han...

Страница 4: ...ndanger property and per sonal safety All local regulations including those referring to national and European standards need to be com plied with when installing this stove Chimney Types Your Dutchwe...

Страница 5: ...he stove to the chimney The chimney itself is a masonry or prefabricated structure that encloses the flue Chimney connectors are used only to make the connection from the stove to the chimney Connecti...

Страница 6: ...himney connector and secure it to the flue collar with three 10 x 1 2 sheet metal screws 2 Secure each joint between sections of chimney con nector including telescoping joints with at least three she...

Страница 7: ...ety degrees and goes back into the fireplace chimney The liner of the fireplace chimney should extend at least to the point at which the chimney connector enters the chimney Follow all the guidelines...

Страница 8: ...combustible spacers at least 25 mm 1 clear of the wall Your Dutchwest ST421 hollow wall pass through 6 2 04 djt 18 450mm Empty Space All Around the Chimney Con nector Sheet Metal Cover One side only S...

Страница 9: ...st 152 mm 6 from the right side and rear It must also provide protection beneath any horizontal runs of the chimney connector including 51 mm 2 to either side Many raised hearths will extend less than...

Страница 10: ...le materials is specified in section 2 of Document J in relation to the clearance of the appliance from the sur face As a general rule the thickness of solid noncom bustible material forming the reces...

Страница 11: ...Bottom Heat Shield is required in many instal lations Refer to the floor protection information found in the Installation Section of this manual Attach the Legs and Heat Shield NOTE To avoid damaging...

Страница 12: ...n the effort of moving the stove over smooth flooring is to slide it on a piece of inverted carpet Move it slowly to ensure the floor is not scratched Retighten all leg fastening hardware ST815 back l...

Страница 13: ...rs Opening the inlet shutters provides air for primary combustion To open the shutters turn the lever clockwise The shutters are all the way open when the lever points to ward the rear at a 9 00 posit...

Страница 14: ...ing in short burn time and dimin ished stove performance If you must burn it mix it in with greener wood to slow the burn Store your firewood under cover to keep it dry Even for short term storage kee...

Страница 15: ...e the firing rate of your heater by altering the air control adjustment range outlined in these directions In some newer homes that are well insulated and weather tight poor draft may result from insu...

Страница 16: ...approximately 25 51 mm 1 2 thick DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE DO NOT BURN GARBAGE OR FLAM MABLE FLUIDS SUCH AS GASOLINE NAPTHA OR ENGINE OIL Also never use gasoline type lantern f...

Страница 17: ...in a metal container with a tight fitting lid ST438 ash pail 7 6 00 djt ST438 ST805 remove ashes 5 04 ST805 Fig 24 Check the ash compartment before reloading the stove Safe Ash Handling Ashes may con...

Страница 18: ...With time and use the door latches will require periodic adjustment Follow this procedure Fig 26 1 Loosen the small locking nut with an open end wrench 2 Use the allen wrench included with the stove t...

Страница 19: ...nuts on the threaded rods that secure the top plate to the inner top of the stove 2 Remove the top plate and open the damper 3 Loosen the adjusting bolt s lock nut Fig 28 4 Loosen the anchor bolt s l...

Страница 20: ...n As Required Inspect the chimney and chimney connector twice monthly and clean if necessary Let the stove cool completely before you inspect the chimney Use a flash light and mirror to sight up the f...

Страница 21: ...d match between all the parts the system works well Wood stove operation depends on natural unforced draft Natural draft occurs when exhaust gas is hotter and therefore lighter than the outdoor air at...

Страница 22: ...in the flue will act as a brake on the exhaust as it flows from the firebox to the chimney cap The ideal pipe and chimney layout is straight up from the stove through a completely straight chimney Use...

Страница 23: ...swing ing the air control open and closed Results here are not instant you may need to wait a few minutes for a change in the air control setting to have an effect on the fire If there is no change t...

Страница 24: ...t to make changes in design materials specifications prices and discontinue colors and products at any time without notice Dutchwest Convection Heater Model 2479CE Ref Description 2479CE 1 Bottom 3000...

Страница 25: ...77 Door Gasket Front Ash and Load Doors 1203589 26 Kaowool 30004713 27 Inner Door 30004712 28 Handle w Lifter Wood 30002787 29 Load Door to June 2005 30002234 Load Door II replaces above 30002440 When...

Страница 26: ...26 Dutchwest Non Catalytic Convection Heater 30003851...

Страница 27: ...by burning salt saturated wood chemically treated wood or any fuel not recommended in the Owners Guide 4 This warranty does not cover a stove repaired by someone other than a Dutchwest Authorized Dea...

Страница 28: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: