background image

1

www.duss.de                                                                      

1

6

8

Translation of the DIA 303 S original operating instructions

Components and control elements

1 · Holder for auxiliary handle
2 · Adjusting dial for speed and impact force
3 · Trigger lock for pushbutton switch
4 · Pushbutton switch on/off
5 · Overload and service indicator
6 · Swivelling side handle
7 · Gear shift lever
8 · Change lever drilling/drilling with soft impact
 

Applications

The

 DIA 303 S diamond core drill

 is suitable for dry diamond core 

drilling with dust extraction into all types of masonry, concrete and 

Operating instructions  

DIA 303 S diamond core drill

Technical data 

DIA 303 S

Power input 

2000 W

Voltage 

230 V 

Current input 

9.4 A

Frequency 

50 - 60 Hz 

Machine weight          

6.9 kg

Speed / impact force under load

1. gear 

420 - 530 rpm / 8480 - 10600 impacts/min

2. gear 

660 - 830 rpm / 13280 - 16600 impacts/min

3. gear 

900 - 1130 rpm / 18080 - 22600 impacts/min

Drilling range with diamond core bit       

52 - 250 mm 

1. gear 

dia. 137 - 202 mm (250 mm in masonry)

2. gear 

dia. 102 - 137 mm

3. gear 

dia. 52 - 102 mm

Max. drilling range      

250 mm

Chuck   

G 1/2

" external thread

Switchable soft impact

Permanent lubrication 
Swivelling side handle and screw-in auxiliary handle 
Pushbutton switch on/off with trigger lock, ensuring non-fatiguing work 
Safety clutch 
Electronic for constant speed and impact force control, full load speed = no load speed 
Speed and impact force infinitely adjustable with adjusting dial
Electronic overload indicator
Service indicator
Self disengaging carbon brushes  
EN 62841 Class II device
Interference-suppresses in accordance with EN 55014

reinforced concrete. Concrete and reinforced concrete must only be 
drilled with soft impact. The user is solely responsible for damages 
which result from improper use.

Electrical connection

To prevent the machine from being started unintentionally during 
care, maintenance or repair operations, and before replacing the 
tool, unplug the machine at the mains socket.  

The machine is a Class II device and is totally insulated. For this 
reason, the housing must never be grounded or drilled with holes, it 
must never be used if damaged, and it must always be kept dry. The 
voltage indicated on the rating plate must agree with the power supply 
voltage. Only use the extension lead with sufficient section approved 

Specifications subject to change

Отзывы: