background image

 

 

Habitat 100H 

 

User Manual 

Version 12/2020 REV1.6 - IV813EN 

 

 

Содержание Habitat 100H

Страница 1: ...Habitat 100H User Manual Version 12 2020 REV1 6 IV813EN...

Страница 2: ......

Страница 3: ...very 9 3 5 Function 10 4 How to use 11 4 1 Assembling 11 4 2 Positioning 13 4 3 Switch air purifier on and off 14 4 4 Power Mode and Silent Mode 15 4 5 Convert to Backlit mode 15 4 6 Turn backlight LE...

Страница 4: ...ments such as offices schools restaurants bars stores or banks and making the environment safer The air disinfection system with UV C technology is highly efficient whisper quiet and can be personaliz...

Страница 5: ...circulation of the device with objects Do not place any objects on the device Do not place flammable substances near the device Do not use the device together with chemical and or flammable substances...

Страница 6: ...Version 12 2020 REV1 6 3 Description 3 1 Overview Fig 1 Habitat 100H overview 1 outer membrane 2 core unit 3 pedestal 4 top unit 5 air outlet 6 switch backlight ON OFF 7 output socket 8 input socket...

Страница 7: ...REV1 6 7 3 2 Information signs Fig 2 Information signs on the device 1 name plate 2 output socket information sign Fig 3 information signs behind maintenance cover 1 UV light warning sign 2 maintenanc...

Страница 8: ...V C source nm 254 life span UV C source h ca 9000 room temperature range C 20 50 humidity range 0 70 max altitude m MSL 2000 outer Viroblock membrane fabric DecoTex AVPGFS 7048AVPGFS weight g m2 215 m...

Страница 9: ...ry 1 1 top unit 1x 2 core unit 1x 3 pedestal 1x 4 inner membrane 2x 5 outer Viroblock membrane 2x 6 power cord 1x 7 daisy chain cable 0 7 m 1x 8 daisy chain cable 2 5 m 1x 9 felt protectors 6x 10 alle...

Страница 10: ...ing renders bacteria particles germs and viruses innocuous Channels inside the panel forward the absorbed air on into the core unit 2 Disinfection The contaminated air is disinfected in the core unit...

Страница 11: ...ncluded felt protectors 4 on the pedestal 3 Remove the maintenance cover 5 on the back side of the core unit The maintenance cover is attached magnetically 4 Place the top unit 6 on the core unit 5 Gu...

Страница 12: ...sewn on rubber lips into the designated rails on the frame to do so Hint Start mounting the membrane at the frame s corners 9 Mount the outer membrane 11 on both sides Slide the sewn on rubber lips in...

Страница 13: ...12 2020 REV1 6 13 4 2 Positioning Position the device as close as possible to the center of the room Respect the minimum distance of 150 cm from large surfaces such as walls furniture etc Do not block...

Страница 14: ...evices 0 40 0 100 12 1 20 80 100 200 25 2 80 120 200 300 38 3 120 160 300 400 50 4 160 200 400 500 63 5 Tab 2 Recommended number of devices per surface and person with room height of 2 5m 4 3 Switch a...

Страница 15: ...operating modes Power Mode Silent Mode The selected operating mode remains active and is not reset when the device is turned off 4 5 Convert to Backlit mode Durst Habitat comes with a special Backlit...

Страница 16: ...so 4 Cover the exposed frame surfaces of the device s top unit Use the included covers 6 Remove the protective film from the adhesive surface Mind the correct hole spacing of the upper and lower cover...

Страница 17: ...amount of processed air are not limited by this conversion Mind the missing absorption surface when positioning the device Fig 6 Air circulation without Backlit membrane left and with Backlit membrane...

Страница 18: ...utput socket 5 input socket 6 power cord 7 switch air purifier ON OFF 1 Position main device and desired number of additional devices 2 Connect first additional device to main device Plug daisy chain...

Страница 19: ...amps of left module defective Replace both UV C lamps of left module UV C lamps of right module defective Replace both UV C lamps of right module UV C lamps of both modules defective Replace all lamps...

Страница 20: ...nd disconnect the power cord 1 2 Remove the maintenance cover 2 on the back side of the core unit The maintenance cover is attached magnetically 3 Unscrew the Phillips head screws 3 to remove the defe...

Страница 21: ...n the lamp socket as indicated in the illustration Remove defective lamps from their socket Dispose of defective and unused lamps properly 6 Push the red latch 6 on the lamp socket as indicated in the...

Страница 22: ...G User Manual Version 12 2020 REV1 6 8 Close previously opened lamp cover 4 Carefully screw in all Phillips head screws 3 9 Reattach the maintenance cover 2 to the back side of the core unit 10 Connec...

Страница 23: ...of the core unit The maintenance cover is attached magnetically 3 Use a flat screwdriver to unscrew the fuse holder cap 3 counterclockwise 4 Pull the defective fuse 4 from the fuse holder cap 5 Inser...

Страница 24: ...tenance and Troubleshooting Habitat 100H 24 2020 Durst Phototechnik AG User Manual Version 12 2020 REV1 6 7 Reattach the maintenance cover 2 to the back side of the core unit 8 Connect the power cord...

Страница 25: ...tion Phillips head screws for lamp cover M3x6 1127188 cylinder head screws for top unit M6x60 1126822 countersunk screw for pedestal M6x12 1127035 UV C lamp 1873861 inner membrane be tex Samba FR AE81...

Страница 26: ...Durst Habitat on durst group com en Habitat Do not hesitate to contact us for questions regarding technical advice repairs or spare parts Europe Durst Phototechnik AG Julius Durst Str 4 39042 Brixen I...

Страница 27: ...Habitat 100H 6 Declaration of Conformity 2020 Durst Phototechnik AG User Manual Version 12 2020 REV1 6 27 6 Declaration of Conformity...

Страница 28: ...Julius Durst Str 11 9900 Lienz Austria P 43 4852 717 77 office durst group com durst group com The latest technical developments are constantly being incorporated into Durst products Descriptions illu...

Отзывы: