Страница 1: ...CR 35 NDT Plus HD CR 35 NDT Plus EN Installation and operating instructions 9000 608 130 02 2206V004...

Страница 2: ...The current version of the installation and operating instructions is available in the Download Center http q r to CR35NDT...

Страница 3: ...rotection cover 18 5 4 CR 35 image plate cassette 19 5 5 CR 35 flexible cassette 19 5 6 NDT plastic cassette 19 5 7 Stylus 19 5 8 Light protection screen 19 Assembly 6 Requirements 20 6 1 Installation...

Страница 4: ...8 12 4 Stylus 38 13 Maintenance 39 13 1 Recommended maintenance schedule 39 Troubleshooting 14 Tips for operators and service techni cians 40 14 1 Poor X ray image 40 14 2 Software error 42 14 3 Fault...

Страница 5: ...symbol The warnings are structured as follows SIGNAL WORD Description of the type and source of danger Here you will find the possible conse quences of ignoring the warning Follow these measures to av...

Страница 6: ...A STD C22 2 NO 61010 1 1 2 Label Fig 1 Laser class 3B Fig 2 Warning laser beams Information about the laser source Information about the laser source Danger to components due to electrostatic discharg...

Страница 7: ...iagno sis 2 3 General safety information Always comply with the specifications of all guidelines laws and other rules and regula tions applicable at the site of operation for the operation of this uni...

Страница 8: ...te keys for D RR NDT products can be found in the down load area at www duerr ndt de document no GA10100002 2 9 Protection from threats from the Internet The unit is to be connected to a computer that...

Страница 9: ...Plus Image Plate Scanner 2 Image plate 3 CR 35 Image plate cassette 4 SDHC memory card 5 Network cable 6 Mains cable 7 Power supply unit 8 Light protection screen mounted on device 9 NDT plastic cass...

Страница 10: ...resolution not available on the USA mar ket HD IP Plus image plate 6x24 cm HD IP Plus image plate 6x48 cm HD IP Plus image plate 10x24 cm HD IP Plus image plate 10x48 cm HD IP Plus image plate 18x24 c...

Страница 11: ...5 flexible cassette 35x43 cm 1 piece NACS100018 Further cassette formats available on request 3 4 Consumables The following materials are consumed during operation of the device and must be reordered...

Страница 12: ...te 35x43 cm 1 piece HR3543CM113 Further image plate formats available on request High resolution XHD XHD image plate 10x24 cm 1 piece XL1024CM113 XHD image plate 10x48 cm 1 piece XL1048CM113 XHD image...

Страница 13: ...unit In accordance with IEC 60825 1 2007 1 Laser source Laser class In accordance with IEC 60825 1 2007 3B Wavelength l nm 635 Output mW 15 Laser source HD CR 35 NDT Plus Laser class in accordance wi...

Страница 14: ...ector RJ45 Type of connection Auto MDI X Cable type CAT5 WLAN connection WLAN technology IEEE 802 11b g Encryption WPA WPA2 Memory card Type SDHC Maximum memory capacity GB 32 File system FAT32 Perfor...

Страница 15: ...her information concerning the various scan modes can be obtained by contacting D RR NDT The basic local resolution can vary depending on the actual x ray source exposure conditions and image plate ty...

Страница 16: ...Native laser spot m 25 HV V 620 Laser Laser level 6 RPM rpm 3000 Pixel binning Off Scan mode name 50 m White IP Pixel size m 50 Native laser spot m 50 HV V 670 Laser Laser level 6 RPM rpm 4000 Pixel b...

Страница 17: ...Scan mode name 100 m White IP Binning Laser Laser level 6 RPM rpm 4000 Pixel binning On Product description 9000 608 130 02 2206V004 EN 15...

Страница 18: ...with the installation and operating instructions this can lead to interference in radio communications Operation of the equipment in a residential area may cause malfunctions to occur on the device Th...

Страница 19: ...reen the image is saved to the memory card and then needs to be transferred to the computer After scanning the image plate runs through the erasure unit Image data still held on the image plate is era...

Страница 20: ...able depending on the particular application to select the matching scanning mode to suit the image plate 5 2 Image plate The image plate stores X ray energy which is re emitted in the form of light...

Страница 21: ...tion functions for the image plate Protection against sunlight and UV light and therefore protection against accidental erasure Protection against mechanical damage Protection against contamination an...

Страница 22: ...cal data 6 2 System requirements For details of the system requirements for computer systems refer to the separate information sheet order number 9000 608 02 or visit the website at www duerr ndt de 6...

Страница 23: ...nit see 4 1 Image plate scanner Setting the unit on a table To prevent errors when scanning the image data install the unit so it is not exposed to vibrations Place the unit on a firm horizontal surfa...

Страница 24: ...o the mains supply The device has no main power switch For this reason the unit must be set up in such a way that the power outlet is easily accessible so that the unit can be unplug ged if necessary...

Страница 25: ...nger available and cannot be activated in the settings until the WLAN stick is installed again To remove the WLAN stick please contact the customer service Combining devices safely Take care when conn...

Страница 26: ...5141 UDP Event protocol data Syslog Port Purpose Service 2005 TCP 23 TCP Diagnosis Telnet SSH 1 The port can vary depending on the con figuration Configuring WLAN on the unit If the unit is to be ope...

Страница 27: ...e Configuring the unit in D Tect Configuring is carried out using CRNetConfig which is automatically installed on installation of D Tect Select Start All Programs D rr NDT CRScan CRNetConfig Click The...

Страница 28: ...rom the Registered Units list Select the mode class Select the mode Click on Scan Image Scan an image plate see 11 2 Scanning the image data via a computer 8 2 Acceptance tests The required tests e g...

Страница 29: ...If the contents of the window cannot be com pletely displayed on the touch screen a scroll bar appears Tap or to move the displayed sec tion of the window 9 2 Using menus The menus integrated in the m...

Страница 30: ...flexible like X ray film How ever the image plates should not be bent Do not scratch the image plates Do not sub ject the image plates to pressure from hard or pointed objects Do not soil the image p...

Страница 31: ...is in the same room as the X ray tube Image plates must only be read using an image plate scanner that is approved by D RR NDT 11 1 X ray The procedure is described using an 18x24 image plate as an e...

Страница 32: ...cover The seal must be on the inactive side of the image plate Close the CR 35 flexible cassette light protec tion cover Where required the correct position of the image plate left or right side can...

Страница 33: ...e image data via a computer Starting the image plate scanner and soft ware Scanning is executed using the D Tect X imaging software For further information on using the imag ing software refer to the...

Страница 34: ...ge data caused by light entering the device Do not remove the CR 35 image plate cassette until the image plate has passed completely through the unit Slide the image plate into the device with both ha...

Страница 35: ...il the image plate is automatically taken up by the unit Scanning progress is displayed on the touch screen The image data is saved automatically The touch screen only shows a preview which provides a...

Страница 36: ...tion Use Help on the touch screen for further information on operating the unit via the touch screen Requirements Memory card SDHC max 32 GB in the slot on the unit Press to switch on the unit Start s...

Страница 37: ...device with both hands until it is automatically taken up by the transport Scanning progress is displayed on the touch screen The image data is saved automatically The touch screen only shows a previ...

Страница 38: ...iews occur due to image size and or exposure conditions For purposes of diagnosis the X ray image must be viewed on a diagnostic monitor After scanning the image plate data is erased Save the X ray im...

Страница 39: ...etely The touch screen is off After you switch off the unit wait 10 s before switching the unit on again 12 Cleaning NOTICE The use of unsuitable agents and methods can damage the unit and accessories...

Страница 40: ...ssette flexible cassette plastic cassette When dirty the surfaces must be cleaned Remove any soiling with a soft lint free cloth that has been dampened with cold tap water To clean use 70 2 propanol i...

Страница 41: ...light protection brush if necessary The oscilloscope must not exceed 600 counts Check the belt drives transport belts and springs and replace if necessary Disassemble the transport drum Remove dust a...

Страница 42: ...a Service Technician X ray image too dark X ray dose too high Check X ray parameters Incorrect brightness contrast settings in the software Adjust the brightness of the X ray image in the software X r...

Страница 43: ...of the X ray beam When taking an X ray make sure there are no metal parts between the X ray tube and the patient Check X ray tube Faulty edge masking in imaging software Deactivate edge masking Softwa...

Страница 44: ...s or clouding Micro scratches on the image plate Replace the image plate Lamination of the image plate becoming detached at the edge Incorrect retainer system used Only use original image plates and f...

Страница 45: ...ith out an intermediate router on the unit Reconnect the router Manually enter the IP address in CRScanConfig and register the unit The IP address of the device is being used by another unit Check the...

Страница 46: ...pply voltage too low Check the mains voltage Loud operating noises after switching on lasting more than 30 seconds Radiation deflector defective Inform a Service Technician Unit not responding The uni...

Страница 47: ...router Another WLAN network is affecting the operation of the unit s WLAN network Change the frequency range of the WLAN network Connecting cable between device and computer not cor rectly connected C...

Страница 48: ...odes to the factory settings via the unit interface or the Imaging Software Error code 1100 Permitted time for scan process exceeded Inform a Service Technician Check the belt drive Check for blockage...

Страница 49: ...back on again Update the firmware Error code 78 Storage medium e g memory card or memory stick is full Transfer the image data to the computer Insert empty storage medium Fault during memory cleanup...

Страница 50: ...endix 15 Settings menu layout Device information1 Device data Dealer information Report Access level1 Operator Administrator Service Technician In house technician Appendix 48 EN 9000 608 130 02 2206V...

Страница 51: ...est date Comment X ray parameters Acquisition type Weld solder seam Casting cast metal piece Touch screen Brightness Touch screen calibra tion Device settings Standby Stand by time Fade out time menu...

Страница 52: ...asure unit Pentaprism PMT Query sensor values Sensors Temperatures Internal device voltages Oscilloscope Check touch screen Display test images Factory settings Reset scanning modes 1 Visible from acc...

Страница 53: ...pend largely on the computer system used and its work load Times stated are approximate Scan mode name BAM Certified Mode 15 15 30 25 m Blue IP High Res White IP 50 m White IP Pixel size m 15 25 50 10...

Страница 54: ...able compression methods can considerably reduce the file size without loss of data Scan mode name BAM Certified Mode 15 15 30 25 m Blue IP High Res White IP 50 m White IP Pixel size m 15 25 50 10 x 2...

Страница 55: ......

Страница 56: ...Hersteller Manufacturer D RR NDT GmbH Co KG H pfigheimer Str 22 74321 Bietigheim Bissingen Germany Fon 49 7142 99381 0 www duerr ndt com info duerr ndt com...