Usage
9.2 Unit with analogue display
Display/handling
1
2
4
3
5
1 GREEN LED
2 RED display
3 Audible signal/melody
4 Reset/service key
5 YELLOW LED
Ready for operation
GREEN LED illuminates
Disposable amalgam container filled to 95 %
Yellow LED lights up
GREEN LED lights up
Audible signal melody sounds
– At a fill level of 95%, the signal melody can be
switched off by pressing the reset button. The
unit is then ready for operation again.
– The yellow LED lights up as a reminder that
the amalgam collector vessel is due to be
changed. The level display is repeated every
time the unit is switched on at the main power
switch.
We recommend changing the amalgam
collector vessel when it reaches 95% full.
Disposable amalgam container filled to 100 %
Yellow LED lights up
Red display flashes
Audible signal melody sounds
Rights
Operator
– Query unit information.
– Change language.
Service techni-
cian
– Query unit information.
– Change language.
– Perform maintenance.
– Perform maintenance
actions.
– Change unit parameters.
i
Press
user authorisations.
i
Select
User
or
Technician
wählen and confirm
with
OK
.
Select maintenance
i
Press
Maintenance
.
The display indicates when the next mainte-
nance is due.
i
Carry out all maintenance work.
i
Press
Maintenance performed
Counter is reset
i
Confirm with
OK
.
Select maintenance actions
i
Press
maintenance actions
.
The display indicates units for which mainte-
nance action can be started.
i
Select the required maintenance action and
confirm with
OK
.
Set compressor start-up pressure
i
Press
settings > unit parameters > compres-
sor start-up pressure
.
i
With
or
Set required value and confirm with
OK
.
Compressor cut off pressure
i
Press
settings > unit parameters > compres-
sor cut off pressure
.
i
With
or
Set required value and confirm with
OK
.
Suction unit afterrunning time
i
Press
settings > unit parameters > suction
machine afterrunning time
.
i
With
or
Set required value and confirm with
OK
.
EN
Содержание Power Tower Silence 200
Страница 1: ...EN 1806V002 A949100002L02 Installation and operating instructions Power Tower Silence 200 ...
Страница 2: ......
Страница 25: ...A949100002L02 1806V002 23 11 Connection media plan PTS 200 Appendix EN ...
Страница 26: ...24 A949100002L02 1806V002 Appendix PTS 200 PC board mit with CA 4 EN ...
Страница 27: ...A949100002L02 1806V002 25 Appendix EN ...
Страница 33: ...A949100002L02 1806V002 31 Appendix Y1 Relief valve EN ...
Страница 34: ...32 A949100002L02 1806V002 Appendix X3 Top display optional X4 Manifold control contact EN ...
Страница 38: ...36 A949100002L02 1806V002 Appendix M5 Drying unit fan Y1 Relief valve Q4 Pressure switch EN ...
Страница 39: ...A949100002L02 1806V002 37 Appendix X4 24 V AC Ablagesteuerkontakt EN ...
Страница 42: ...40 A949100002L02 1806V002 Appendix Y1 Relief valve EN ...
Страница 43: ...A949100002L02 1806V002 41 Appendix X4 24 V AC manifold control contact EN ...
Страница 46: ...44 A949100002L02 1806V002 Appendix EN ...
Страница 47: ......