Page 25 of 43
6 Fault reports and solutions
Reset the fault by pressing and holding the
ON/OFF button until you hear a
beep.
6.1.1 ERROR 1
This report appears if there is no ignition.
Refer to 5.3 No ignition.
6.1.2 ERROR 5
No pellets. The flue gas temperature is too low. Possible causes include:
- The tank is empty. Fill the tank with pellets.
- There is a defect, refer to 5.2 No pellet supply.
6.1.3 ERROR 6
This fault report has one of two causes:
- Component 7.1.6 Pressure monitoring device.
- Component 7.1.7 Maximum thermostat.
6.1.4 ERROR 8
This fault report is triggered if the current is interrupted when the stove is in the ignition,
operating or cooling phase. You can reset this fault by pressing and holding the
ON/OFF
button until you hear a beep.
Possible causes: refer to 5.1 No power supply.
6.1.5 ERROR 9
- This fault report appears if no rotations of the flue gas fan are measured. Check
whether the fan rotates or not. You can rotate the fan using the component test (refer
to 8.1.2)
- The blower does not rotate (component 7.1.9 Blower). Check that the fan is not
blocked. Check the plugs and cables if the fan is not blocked.
- The fan is rotating. Check the encoder (7.1.11). This is the sensor that measures
blower RPM. To check this, refer to (8.1.3)
6.1.6
‘Service’
This report indicates that the stove has been burning for 1200 hours. The stove
indicates this as a reminder that maintenance must be carried out. You can find the
resetting of this report at (8.1.6).