Maintenance
124
Service Instructions 667 PREMIUM - 03.0 - 01/2018
15.3 Servicing the pneumatic system
15.3.1 Setting the operating pressure
Proper setting
Refer to the
Technical data
) chapter for the permissible
operating pressure. The operating pressure cannot deviate by more than
± 0.5 bar.
Check the operating pressure on a daily basis.
Fig. 86: Setting the operating pressure
To set the operating pressure:
1.
Pull the pressure controller (1) up.
2.
Turn the pressure controller until the pressure gage (2) indicates the
proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
3.
Push the pressure controller (1) down.
NOTICE
Property damage from incorrect setting!
Incorrect operating pressure can result in damage to the machine.
Ensure that the machine is only used when the operating pressure
is set correctly.
(1)
- Pressure controller
(2)
- Pressure gage
①
②
Содержание 667 PREMIUM
Страница 1: ...667 PREMIUM Service Instructions...
Страница 10: ...About these instructions 8 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 28: ...Working basis 26 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 70: ...Thread cutter 68 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 98: ...Programming 96 Service Instructions 667 PREMIUM 03 0 01 2018 Fig 62 Connecting adapter to DACcomfort...
Страница 120: ...Programming 118 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 130: ...Maintenance 128 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 132: ...Decommissioning 130 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 134: ...Disposal 132 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 146: ...Troubleshooting 144 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 149: ......