Programming
60
Service Instructions 2112-5 - 00.0 - 02/2020
Terminal assignment for S23 (needle thread monitor, plug X2)
• yellow: 1
• green: 2
• white:3
• brown: 4
8.6 Global parameters
The following global parameters can be programmed:
S22
22
Photocell stacking
height
Photocell
NPN
X13 Pin22
S23
23
Needle thread monitor
Touch
probe
Plug X2
S25
25
Remaining thread
monitor
Photocell
NPN
X13 Pin25
No.
Parameter
Value
Unit
01
Till clamp sideways fwd
Scan and part pickup after clamp movement forward
0.3
s
02
Till clamp down
Lower clamp after clamp movement forward for part
pickup
0.1
s
03
Till vacuum off
Switch vacuum off after clamp down
0.2
s
04
Thrd length, bobbin full
003
m
05
Till clamp inserting
Clamp insertion delay
0.2
s
06
Sewing end -> Cl. sideways
Clamp movement sideways to the rear after sewing is
completed
0.1
s
07
Time after clamp open
Clamp movement right to programmed position after
clamp up
0.1
s
10
Till folding cl. closed
After folder right and down, time until folding clamp
closes
0.5
s
11
Till folder lift up
After folding clamp closes, time until folder up
0.2
s
12
Till folder swings left
After folder up, time until folder swings left and rotates
0.2
s
Switch
Input
number
Switch
type
Version
Signal
input
Содержание beisler 2112-5
Страница 1: ...Service Instructions...
Страница 8: ...About these instructions 6 Service Instructions 2112 5 00 0 02 2020...
Страница 40: ...Setting up the machine 38 Service Instructions 2112 5 00 0 02 2020...
Страница 76: ...Programming 74 Service Instructions 2112 5 00 0 02 2020...
Страница 84: ...Maintenance 82 Service Instructions 2112 5 00 0 02 2020...
Страница 86: ...Decommissioning 84 Service Instructions 2112 5 00 0 02 2020...
Страница 88: ...Disposal 86 Service Instructions 2112 5 00 0 02 2020...
Страница 96: ...Technical data 94 Service Instructions 2112 5 00 0 02 2020...
Страница 103: ......