Decommissioning
Operating Instructions 610-10/630-10 - 01.0 - 01/2021
109
8
Decommissioning
You need to perform a number of activities if the machine is to be
shut down for a longer period of time or completely decommis-
sioned.
To decommission the machine:
1.
Switch off the machine.
2.
Unplug the power plug.
3.
If applicable, disconnect the machine from the compressed
air supply.
4.
Remove residual oil from the oil pan using a cloth.
5.
Cover the control panel to protect it from contamination.
6.
Cover the controller to protect it from soiling.
7.
Cover the entire machine if possible to protect it from contam-
ination and damage.
WARNING
Risk of injury from a lack of care!
Serious injuries may occur.
ONLY clean the machine when it is switched off.
Allow ONLY trained personnel to disconnect the
machine.
CAUTION
Risk of injuries from contact with oil!
Oil can cause a rash if it comes into contact with
skin.
Avoid skin contact with oil.
If oil has come into contact with your skin, wash
the affected areas thoroughly.
Содержание 610-10
Страница 1: ...610 10 630 10 Operating Instructions...
Страница 6: ...Table of Contents 4 Operating Instructions 610 10 630 10 01 0 01 2021...
Страница 16: ...Safety 14 Operating Instructions 610 10 630 10 01 0 01 2021...
Страница 44: ...Operation Operating Instructions 610 10 630 10 01 0 01 2021 42...
Страница 84: ...Settings via software Operating Instructions 610 10 630 10 01 0 01 2021 82...
Страница 96: ...Maintenance Operating Instructions 610 10 630 10 01 0 01 2021 94...
Страница 112: ...Decommissioning 110 Operating Instructions 610 10 630 10 01 0 01 2021...
Страница 116: ...Disposal 114 Operating Instructions 610 10 630 10 01 0 01 2021...
Страница 136: ...Troubleshooting Operating Instructions 610 10 630 10 01 0 01 2021 134...
Страница 140: ...Appendix Operating Instructions 610 10 630 10 01 0 01 2021 138 Fig 65 Dimensions for manufacturing a table top 2...
Страница 147: ......