Maximum Operating Pressure – 700 bar 

 

Instruction Manual  

30 Series Auto, 2 Speed Electric Power Unit 
Model – PEM3024

 

Содержание 30 PEM3024 Series

Страница 1: ...186 Granite Street GEEBUNG QLD 4034 Australia sales absoluteequipment com au Phone 61 7 3865 4006 Fax 61 7 3102 6288 Maximum Operating Pressure 700 bar Instruction Manual 30 Series Auto 2 Speed Elect...

Страница 2: ...s can be made Any power unit that has been or suspected to have been subject to a shock load should be removed from service immediately until inspected by a Durapac authorised service centre Owners an...

Страница 3: ...lers Use the carrying handle or other means of safe transport Hydraulic equipment must only be serviced by a qualified hydraulic technician For repair service contact the Durapac authorised service ce...

Страница 4: ...gnated objects and wet paint Never paint a coupler or hose FAILURE TO HEED THESE WARNINGS MAY RESULT IN PERSONAL INJURY AS WELL AS PROPERTY DAMAGE 4 0 Installation IMPORTANT Always secure threaded por...

Страница 5: ...y are tight and leak free 5 1 2 Check oil level in reservoir 5 1 3 Ensure the air breather is fitted to the power unit CAUTION The vent plug must be open whenever the power unit is running 5 2 Lifting...

Страница 6: ...e non hardening pipe thread compound when servicing connections Dirt sand etc will quickly ruin any hydraulic system Ensure that couplings are clean and free of foreign matter After each use clean cou...

Страница 7: ...once a year or every 300 hours of use 6 3 1 Repeat Steps 6 1 1 to 6 1 3 above 6 3 2 Pour used fluid into a sealable container 6 3 3 Repeat Steps 6 1 3 to 6 1 6 above 6 3 4 Dispose of fluid in accorda...

Страница 8: ...wer unit reservoir Refer to 6 1 Adding Hydraulic Fluid Fill and bleed the system Power unit runs but will not pump oil Power unit is not primed Run power unit a few minutes tipping from side to side E...

Страница 9: ...and bleed the system Application responds to pressurised fluid but system does not maintain pressure Leaky connection Clean reseal with thread sealant and tighten connection Leaking cylinder seals Rep...