EWM-2SS-DAD/22E-PN
89475/119 ETM
Duplomatic MS
▪
EWM-2SS-DAD/22E-PN Start-up Manual
–
89475-PN/119 ETM --- Mar 2019
37
DC:DV
This parameter is used to define the deactivation point (DV = deactivation value)
Within the deactivation window no compensation value will be calculated (frozen
state). DC:AV = 0 should be used for best positioning, but
“limit cycling“ can occur.
This value should be set to 50 % of an acceptable error.
DC:CR
The output range of the DC function will be limited (CR = control range) by this
parameter.
PROCESS DATA (monitoring)
The process data are variables which can be continuously observed on the monitor or on the
oscilloscope.
Command
Description
Unit
WA1
W1
X1
E1
V1
U1
ES
WA2
W2
X2
E2
V2
U2
External command position axis 1
Actual command position after ramp function axis 1
Feedback position axis 1
Control error axis 1
Speed set point axis 1
Control signal axis 1
Synchronisation error
External command position axis 2
Actual command position after ramp function axis 2
Feedback position axis 2
Control error axis 2
Speed set point axis 2
Control signal axis 2
mm
mm
mm
mm
%
%
mm
mm
mm
mm
mm
%
%