www.factorybuysdirect.com
9
200376-01A
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri-
mary heat source. If you have a
central heating system, you may
run system’s circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualified ser-
vice person must install heater.
Follow all local codes.
WARNING: Before installing
in a solid fuel burning fireplace,
the chimney flue and firebox
must be cleaned of soot, creo-
sote, ashes and loose paint by
a qualified chimney cleaner.
Creosote will ignite if highly
heated. A dirty chimney flue may
create and distribute soot within
the house. Inspect chimney flue
and firebox for damage. If dam-
aged, repair flue before operat-
ing heater.
WARNING: Seal any fresh
air vents or ash clean-out doors
located on floor or wall of fire-
place. If not, drafting may cause
pilot outage or sooting. Use a
heat-resistant sealant. Do not
seal chimney flue damper.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, cloth-
ing, or other flammable objects
are less than 36" from the front,
42" from top, or 16" from sides
of the heater.
• in high traffic areas
• in windy or drafty areas
CAUTION: This heater cre-
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as to-
bacco smoke, aromatic candles,
cleaning fluids, oil or kerosene
lamps, etc.) in the air exist, may
discolor walls or cause odors.
NOTICE: State or local codes
may only allow operation of this
appliance in a vented configura-
tion. Check your state or local
codes.
WARNING: This appliance is
designed for installation in only
a solid-fuel burning masonry or
UL 127 factory-built fireplace or
in a listed ventless firebox enclo-
sure. Exception: DO NOT install
this appliance in a factory-built
fireplace that includes instruc-
tions stating it has not been
tested or should not be used
with unvented gas logs.