Infinity™
Series Servo Ultrasonic Press Systems QUICK START GUIDE
27
Removing the Ultrasonic Stack Module
For model 43NTLA (15 kHz):
Perform the following steps, depending on the model. The first two steps are necessary to ensure that no
power will be accidentally applied while removing the stack.
1.
Activate the E-STOP (Abort) switch on the front of the press base shown in Fig. 4-31.
2.
Power down the generator by placing the AC switch in the “0” position.
3.
Push the button on the bottom of the transducer door as shown in Fig. 4-32 by the arrow labeled 1. The door latch
should release.
4.
Grip the transducer door on both sides and pull down and out as shown in Fig. 4-32 by arrows 2 and 3.
5.
remove the 6 mm hex wrench, Dukane part number 809-721-0013, stored on the inside of the door as shown in
Fig. 4-33, then set the door aside.
6.
Use the wrench to loosen the (2) screws shown in Fig. 4-34.
7.
Pull the transducer clamp bar straight out as shown in Fig. 4-35 by arrow 1, then rotate it 180 degrees counter-
clockwise and push it back in as shown by arrows 2 and 3. The clamp should rest as shown in Fig. 4-36.
8.
Pull the stack out of the press using the fixed handle.
Figure 4-31
E-Stop Button (Abort)
Figure 4-32
Door release Button