Page 17
Section 3 – Installation
Dukane Manual Part No. 403-608-00
Connecting Cables
Basic Connections
Complete these basic connections for the standard con-
figuration as shown below:
•
AC Line Input
•
iQLinQ
™
•
Ultrasound Outputs
•
Grounding
Details about the various system connectors and their pin
assignments are covered in the next section.
1. Wire the AC line connector, and attach it to the gen-
erator’s power inlet connector, matching the power
source line, ground, and neutral with the generator’s
line, ground, and neutral connector pins -
A
in Figure
3–4. (See Figure 2-1 also.)
2. Connect the appropriate cable from the PLC to the
Ethernet/IP Modbus -
B
in Figure 3-2, or ANYBUS
module port for
iQLinQ
™
control of the generator.
3. Attach high–voltage coaxial ultrasound cables (from
the ultrasonic probes) , the ultrasound output connec-
tors -
C
in Figure 3-2.
4. Connect the included ground wire from the grounding
stud,
D
in Figure 3-2, to earth ground.
5. Connect the included E-STOP terminal block to a switch
or jumper the two connections together (
E
in Figure
3-2). Plug the terminal block into the E-Stop port.
Figure 3-2
Generator Front View
NOTE
AC Power Inlet
Line voltage required for the generator is
100-240VAC at 50/60 Hz and 15 Amps
Maximum.The unit does not include a
power switch, and is powered ON whenever
the AC line power is live.
The unit can be switched ON/OFF with a
user-supplied AC circuit breaker wired to
the AC power inlet connection.
NOTE
Connecting Cables
Two-piece pluggable terminal block con-
nectors are used for the the AC Power Inlet
connections.
This type of connector allows the wiring to
be attached to the spring loaded terminal
connector, which plugs into the mating con-
nector on the
iQ
Auto system front panel.
In the event a field replacement unit is
required, the terminal connectors with the
wires can be easily detached and then
plugged into the replacement unit.
See NOTE on
Page 18 .
Grounding Stud
E-STOP
Power Inlet
D
Ethernet/IP Modbus port
B
A
E
U/S Connectors
C
Содержание Auto-Plus MPC iQ Series
Страница 33: ...Page 27 Section 5 Options Dukane Manual Part No 403 608 00 SECTION 5 Options Heat Sink 29 Distance Option 30 ...
Страница 41: ...Section 7 Contacting Dukane Page 35 Dukane Manual Part No 403 608 00 SECTION 7 Contacting Dukane ...
Страница 57: ...Index Page 51 Dukane Manual Part No 403 608 00 Index ...