Page 57
Section 6 - Specifications
Dukane Manual Part No. 403-610-02
AC Power Requirements
Generator
The
AC line voltage and current needed depends on which generator has been chosen for your system. See the table below
.
Operating
Frequency
Generator
Model Number
Overload
Power
Ratings
(W
atts)
Input
AC Power Requirements
Nominal AC
Volt
at Maximum RMS Current
North America/Japan
AC Outlet Rating
Output
Voltage
(Nominal)
Output
Current
(Max)
15kHz
15XX360-4R-XX
3600
380-480V 50/60 Hz @ 8
Amps*
20A
or 30A
(3 Phase)
1100
3.6
15kHz
15XX500-4R-XX
5000
380-480V 50/60 Hz @ 10
Amps
20A
or 30A
(3 Phase)
1100
5.0
15kHz
15XX360-2R-XX
3600
200-240V 50/60 Hz @ 19
Amps
20A
or 30A
1100
3.6
15kHz
15XX500-2R-XX
5000
200-240V 50/60 Hz @ 26
Amps
30A
1100
5.0
20kHz
20XX300-4R-XX
3000
380-480V 50/60 Hz @ 7
Amps
20A
or 30A
(3 Phase)
1300
2.5
20kHz
20XX360-4R-XX
3600
380-480V 50/60 Hz @ 8
Amps
20A
or 30A
(3 Phase)
1300
3.0
20kHz
20XX500-4R-XX
5000
380-480V 50/60 Hz @ 10
Amps
20A
or 30A
(3 Phase)
1100
5.0
20kHz
20XX360-2R-XX
3600
200-240V 50/60 Hz @ 19
Amps
20A
or 30A
1300
3.0
20kHz
20XX500-2R-XX
5000
200-240V 50/60 Hz @ 26
Amps
30A
1100
5.0
20kHz
20XX120-UR-XX
1200
100-240V 50/60 Hz @ 15
Amp
15A
1300
1.0
20kHz
20XX180-2R-XX
1800
200-240V 50/60 Hz @ 10
Amps
15A
1300
1.5
20kHz
20XX260-2R-XX
2600
200-240V 50/60 Hz @ 15
Amps
15A
1300
2.2
25kHz
25XX120-UR-XX
1200
100-240V 50/60 Hz @ 15
Amps
15A
1000
1.3
25kHz
25XX200-2R-XX
2000
200-240V 50/60 Hz @ 1
1
Amps
15A
1000
2.2
30kHz
30XX120-UR-XX
1200
100-240V 50/60 Hz @ 15
Amps
15A
850
1.6
30kHz
30XX180-2R-XX
1800
200-240V 50/60 Hz @ 10
Amps
15A
850
2.3
35kHz
35XX120-UR-XX
1200
100-240V 50/60 Hz @ 15
Amps
15A
850
1.6
40kHz
40XX120-UR-XX
1200
100-240V 50/60 Hz @ 15
Amps
15A
750
1.8
NOTES:
1.
An X used above in the Model Numbers is a “wildcard” character meaning any valid character code combination.
2. Maximum line current requirement is specified at the minimum nominal
AC line voltage and the rated power level.
3. For the 2600 watt model, if the input line voltage is between 180-190V
, the output is reduced to 2400 watts.
4.
For 380-480 V
AC generators, the ex24V power supply that is connected to the +24V
generator input shall be listed or labeled with 3rd party North
America marking (UL, CSA,
TUV
, etc).
Table 6- II
Generator
AC Power Requirements