6
6.
VISUAL FEEDBACK
SIREN
CE100-8 / CE100-3GSM
CE60-3GSM
1 long flash
Total arming
Total arming
1 long flash + 1 short flash
Partial 1 arming
Partial arming
1 long flash + 2 short flashes
Partial 2 arming
Outdoor arming
1 long flash + 3 short flashes
Partial 3 arming
-
3 short flashes
Disarming
Disarming
7.
MAINTENANCE
By sending to the control panel this command, the siren enter in “maintenance” mode” allowing to open the cover without tamper alarm.
Start maintenance
: when the siren receives the “start maintenance” radio code, emits some “beep” and blinks indicating that now it is
possible to open the cover without tamper alarm. The max time available is about
4 minutes
.
Stop maintenance
: when the siren receives the “stop maintenance” radio code, enable the tamper control, emits some “beep” and blinks
long one time.
8.
TAMPER
The tamper alarm is active 24 H/24, also at system disarmed (excluded the case of “maintenance” function).
When the siren cover opens, the tamper radio code is sent to the control panel and both start to sound.
Once the tamper alarm is send, it is
disabled until the next ARMING
of the system.
Thus, in case of tamper alarm, remember that – to enable it again – it is necessary to arm at least one time the alarm system.
Note
: when the siren is new or after a RESET, to enable the tamper it is necessary to arm at least once time.
Note
: the tamper switch is used to start the “by detection” learning when
DIP2
=
ON
.
To disable the tamper, short the tamper terminals with a piece of wire.
9.
LOW BATTERY
The siren signals its battery level is under the minimum threshold by a quick blinking of the LEDs for some seconds at disarming (after the
three blinks for “disarming” feedback).
The siren sends a special “low battery” radio code (LWB) to the control panel, which perform proper actions (visualization on display and
sending of SMS).
10.
WARNINGS
BEFORE TO INSTALL THE SIREN, VERIFY THE RADIO RANGE OF THE CONTROL PANEL FROM THE INSTALLATION
POSITION.
THE INSTALLER MUS FOLLOW CURRENT REGULATION