background image

6.

 

VISUAL FEEDBACK 

 

SIREN 

CE100-8 / CE100-3GSM 

CE60-3GSM 

1 long flash 

Total arming 

Total arming 

1 long flash + 1 short flash 

Partial 1 arming 

Partial arming 

1 long flash + 2 short flashes 

Partial 2 arming 

Outdoor arming 

1 long flash + 3 short flashes 

Partial 3 arming 

3 short flashes 

Disarming 

Disarming 

 
 
 

7.

 

MAINTENANCE 

By sending to the control panel this command, the siren enter in “maintenance” mode” allowing to open the cover without tamper alarm. 

Start maintenance

: when the siren receives the “start maintenance” radio code, emits some “beep” and blinks indicating that now it is 

possible to open the cover without tamper alarm. The max time available is about 

4 minutes

Stop maintenance

: when the siren receives the “stop maintenance” radio code, enable the tamper control, emits some “beep” and blinks 

long one time. 
 
 
 

8.

 

TAMPER 

The tamper alarm is active 24 H/24, also at system disarmed (excluded the case of “maintenance” function). 
When the siren cover opens, the tamper radio code is sent to the control panel and both start to sound. 
Once the tamper alarm is send, it is 

disabled until the next ARMING

 of the system. 

Thus, in case of tamper alarm, remember that – to enable it again – it is necessary to arm at least one time the alarm system. 

Note

: when the siren is new or after a RESET, to enable the tamper it is necessary to arm at least once time. 

Note

: the tamper switch is used to start the “by detection” learning when 

DIP2

 = 

ON

To disable the tamper, short the tamper terminals with a piece of wire. 
 
 
 

9.

 

LOW BATTERY 

The siren signals its battery level is under the minimum threshold by a quick blinking of the LEDs for some seconds at disarming (after the 
three blinks for “disarming” feedback). 
The siren sends a special “low battery” radio code (LWB) to the control panel, which perform proper actions (visualization on display and 
sending of SMS). 
 
 
 

10.

 

WARNINGS 

 

BEFORE TO INSTALL THE SIREN, VERIFY THE RADIO RANGE OF THE CONTROL PANEL FROM THE INSTALLATION 
POSITION. 

 

THE INSTALLER MUS FOLLOW CURRENT REGULATION 

Содержание VV-ZELA-RB

Страница 1: ...TECHNICAL 3 TERMINALS 3 LED 3 DIP SWITCH FUNCTIONS 4 4 RESET 4 5 PAIR THE SIREN WITH THE CONTROL PANEL LEARNING 5 CONTROL PANELS WITH BI DIRECTIONAL LEARNING FUNCTION 5 CONTROL PANELS WITHOUT THE BI...

Страница 2: ...rens for use with any control panel Received radio codes from control panel or transmitter System armed single long blink of the siren lamp System disarmed three short blinks of siren lamp Alarm siren...

Страница 3: ...nk PARTIAL 1 long 1 short blink PARTIAL 2 long 2 short blinks PARTIAL 3 long 3 short blinks DISARMED 3 blinks RADIO COMMUNICATION Frequency 433 92 MHz Range 100 m open filed Power 10 mW TEMPERATURE 5...

Страница 4: ...rvision off Supervision on DIP4 ALARM BLOCK COUNTER The siren sounds for max 5 alarms each alarm sound lasts about 1 minute during the same arming then stops the sounds until the next arming It is pos...

Страница 5: ...a beep and switch off the lamp Close the cover of the siren 6 In case of errors repeat the procedure CONTROL PANELS WITHOUT THE BI DIRECTIONAL LEARNING FUNCTION THE CONTROL PANELS AN VERSION MUST BE...

Страница 6: ...se of maintenance function When the siren cover opens the tamper radio code is sent to the control panel and both start to sound Once the tamper alarm is send it is disabled until the next ARMING of t...

Страница 7: ...OR ALKALINE 7 5 V 12 Ah NOT INCLUDED HANDLE WITH CARE DANGER OF EXPLOSION AND FIRE DO NOT DISPOSE THE BATTERY IN FIRE DO NOT WELD OR DAMAGE THE BATTERY REPLACE ONLY WITH THE SAME BATTERY TYPE RESPECT...

Страница 8: ...ler when buying a new equivalent device in relation of one to one or one to none for the equipment having the larger side less than 25 cm Appropriate separate collection of the disused equipment for r...