Duevi VV-ZELA-RB Скачать руководство пользователя страница 3

3.

 

TECHNICAL 

 

POWER SUPPLY 

Battery: lithium 7,2 V - 13 Ah or alkaline 7,5 V - 12 Ah 
Batteries not provided 

ABSORPTION 

Stand-by: 73 µA     Alarm: 850 mA 

ALARM CYCLES 

5 cycles

 

SINGLE ALARM TIME 

About 1 min 

ACOUSTIC POWER 

115 dB/m 

SIGNALLING 

TOTAL    > single long blink 
PARTIAL 1  > long + 1 short blink 
PARTIAL 2  > long + 2 short blinks 

PARTIAL 3    > long + 3 short blinks 
DISARMED    > 3 blinks 
 

RADIO COMMUNICATION 

Frequency: 433,92 MHz 

 

Range: 100 m (open filed) 

 

Power: 10 mW 

TEMPERATURE 

-5 °C / +45 °C 

DIMENSION 

310 (H) x 210 (L) x 85 (P) mm 

 

 

 

TERMINALS 

 

LED 

 

TMP 

Tamper (to disable the tamper short-circuit the terminal) 

SIR 

Siren speaker 

BAT 

Battery 

ANT 

Antennas 

LED1 

High power LEDs for blinking signalling 
All LEDs light simultaneously 

LED2 
LED3 
LED4 

Содержание VV-ZELA-RB

Страница 1: ...TECHNICAL 3 TERMINALS 3 LED 3 DIP SWITCH FUNCTIONS 4 4 RESET 4 5 PAIR THE SIREN WITH THE CONTROL PANEL LEARNING 5 CONTROL PANELS WITH BI DIRECTIONAL LEARNING FUNCTION 5 CONTROL PANELS WITHOUT THE BI...

Страница 2: ...rens for use with any control panel Received radio codes from control panel or transmitter System armed single long blink of the siren lamp System disarmed three short blinks of siren lamp Alarm siren...

Страница 3: ...nk PARTIAL 1 long 1 short blink PARTIAL 2 long 2 short blinks PARTIAL 3 long 3 short blinks DISARMED 3 blinks RADIO COMMUNICATION Frequency 433 92 MHz Range 100 m open filed Power 10 mW TEMPERATURE 5...

Страница 4: ...rvision off Supervision on DIP4 ALARM BLOCK COUNTER The siren sounds for max 5 alarms each alarm sound lasts about 1 minute during the same arming then stops the sounds until the next arming It is pos...

Страница 5: ...a beep and switch off the lamp Close the cover of the siren 6 In case of errors repeat the procedure CONTROL PANELS WITHOUT THE BI DIRECTIONAL LEARNING FUNCTION THE CONTROL PANELS AN VERSION MUST BE...

Страница 6: ...se of maintenance function When the siren cover opens the tamper radio code is sent to the control panel and both start to sound Once the tamper alarm is send it is disabled until the next ARMING of t...

Страница 7: ...OR ALKALINE 7 5 V 12 Ah NOT INCLUDED HANDLE WITH CARE DANGER OF EXPLOSION AND FIRE DO NOT DISPOSE THE BATTERY IN FIRE DO NOT WELD OR DAMAGE THE BATTERY REPLACE ONLY WITH THE SAME BATTERY TYPE RESPECT...

Страница 8: ...ler when buying a new equivalent device in relation of one to one or one to none for the equipment having the larger side less than 25 cm Appropriate separate collection of the disused equipment for r...